GBC SavantAA

Double-beam AAS from GBC Scientific Equipment: Ebert-Fastie 333 mm, 175–900 nm, 1800 line/mm, 8-lamp turret, Hyper-Pulse background correction.

Key specifications

Optical system
Double beam AAS
Monochromator
Ebert-Fastie 333 mm
Wavelength range
175–900 nm
Grating
1800 line/mm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The GBC SavantAA is GBC Scientific Equipment’s double-beam atomic absorption spectrometer. The Ebert-Fastie monochromator is 333 mm with a 175–900 nm range and an 1800 line/mm grating. An 8-lamp turret and Hyper-Pulse background correction sit on the optical bench. GBC states >0.9 abs for 5 mg/L Cu with RSD <0.5%.

Sample introduction is an all-titanium burner and a platinum-iridium nebulizer. GBC is an Australian manufacturer, founded in 1978, with operations in Melbourne and Penang. The SavantAA is the elemental flame bench Al-Shaker specifies from that line.

Al-Shaker specifies SavantAA versus Quantima or OptiMass 9600, the first lamp set, and the introduction path, then installs, trains, and supports the spectrometer across Jordan, the GCC, and MENA.

Specifications

Technical specifications

8 parameters

Optics

Optical system
Double beam AAS
Monochromator
Ebert-Fastie 333 mm
Wavelength range
175–900 nm
Grating
1800 line/mm

Source

Lamp turret
8-lamp

Background

Correction
Hyper-Pulse

Sample introduction

Burner / nebulizer
All-titanium / Pt-Ir

Performance

Cu 5 mg/L
>0.9 abs, RSD <0.5%
Features

Key features

  • 01

    Ebert-Fastie optics

    333 mm monochromator, 175–900 nm, 1800 line/mm — a double-beam AAS, not a single-beam teaching unit.

  • 02

    Hyper-Pulse correction

    Background correction on an 8-lamp turret so the method can change element without rebuilding the lamp house.

  • 03

    Titanium burner, Pt-Ir nebulizer

    All-titanium burner and platinum-iridium nebulizer for the flame path GBC publishes on this page.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.