Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: GeminAA / GeminAA Ultra

GBC GeminAA Series

The GeminAA series combines a flame and a graphite furnace atomizer in one compact AAS, with software-controlled switching between the two in under two seconds.

Key specifications

Wavelength range
190-900 nm
Grating
1800 lines/mm, blaze 250 nm
Wavelength accuracy
±0.1 nm
Spectral bandwidth
GeminAA: 5 levels (0.1, 0.2, 0.4, 1.0, 2.0 nm); GeminAA Ultra: 6 levels (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm)
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The GeminAA integrates the optics, flame atomizer, graphite furnace, furnace power supply and control electronics into a single tandem instrument, so one computer and one software platform control both techniques. A suspended optical system limits the effect of bench vibration and temperature change.

The GeminAA Ultra adds a true double-beam optical system for improved optical stability. Both models use a six-lamp turret with automatic alignment and peaking, and deuterium background correction with optional self-absorption correction.

Specifications

Technical specifications

12 parameters

Optics

Wavelength range
190-900 nm
Grating
1800 lines/mm, blaze 250 nm
Wavelength accuracy
±0.1 nm
Spectral bandwidth
GeminAA: 5 levels (0.1, 0.2, 0.4, 1.0, 2.0 nm); GeminAA Ultra: 6 levels (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm)

Flame

Flame method precision (RSD)
<= 0.45%
Burner options
50 mm stainless steel and 100 mm interchangeable all-titanium

Graphite furnace

Temperature range
Room temperature to 3000 °C
Detection limit (Cd)
0.2 x 10^-12 g
Temperature rise rate
Optical control >= 3000 °C/s; max power >= 2000 °C/s
Temperature program
Max 20 steps (step, slope, flat modes)

Background correction

Modes
Deuterium lamp; self-absorption (optional)

Automation

Flame/furnace changeover
Under 2 seconds, software controlled
Features

Key features

  • 01

    Flame and graphite furnace in one

    Routine flame work and trace-level furnace analysis on one platform.

  • 02

    Automated changeover

    Software switches techniques in under 2 seconds with no manual reconfiguration.

  • 03

    Suspended optical system

    Reduces the influence of bench vibration and temperature change.

  • 04

    Six-lamp turret

    Automatic lamp alignment and peaking.

  • 05

    GeminAA Ultra double beam

    True double-beam optics for added optical stability.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.