Al-Shaker for Scientific and Medical Supplies

Positive Pressure SPE Processor

PCI-made positive-pressure SPE: 48 / 96 / 144 individually regulated positions, 1 mL cartridges, dual extract-versus-dry pressure, collection rack and waste.

Key specifications

Positions
48 / 96 / 144
Cartridge
1 mL
Pressure
Dual settings — extraction vs column drying
Hardware
Collection rack + waste reservoir
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

PCI Analytics’ positive-pressure SPE sample processor is published as an indigenous manifold for bioanalytical, bioequivalence, food-assay, and toxicology sample preparation. Catalogue models SPE 48 Plus, SPE 96 Plus, and SPE 144 Plus take 1 mL cartridges as standard. Positions are individually regulated — 48 (4 × 12), 96 (8 × 12), or 144 (12 × 12). Dual settings let the user set different pressures for extraction and column drying. Each model includes one collection rack for a stated test-tube size and a waste reservoir. A single switch raises and lowers the sample racks and makes an airtight seal. PCI states each hole in the manifold is restricted so pressure stays constant even when positions are empty, and that positive pressure improves flow of viscous samples such as plasma or serum versus vacuum manifolds.

Al-Shaker specifies 48 versus 96 versus 144 and the first 1 mL cartridge set, then installs and supports the processor across Jordan, the GCC, and MENA.

Specifications

Technical specifications

4 parameters

Positions
48 / 96 / 144
Cartridge
1 mL
Pressure
Dual settings — extraction vs column drying
Hardware
Collection rack + waste reservoir
Features

Key features

  • 01

    48 / 96 / 144 × 1 mL

    SPE 48 Plus, 96 Plus, and 144 Plus — individually regulated holes, 1 mL cartridges standard.

  • 02

    Extract versus dry

    Dual pressure settings so elution and column drying are not the same regulator stop.

  • 03

    Collection rack and waste

    One collection rack plus a waste reservoir; a single switch seals the racks airtight.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support