SP-IAA320 Atomic Absorption Spectrophotometer

Double beam flame atomic absorption spectrophotometer covering 190 to 900 nm, with deuterium background correction and support for flame emission, graphite furnace and hydride methods.

Key specifications

Model
SP-IAA320
Atomization System
Flame Atomization System
WL range
190-900nm
WL accuracy
≤±0.5nm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SP-IAA320 is a double beam atomic absorption spectrophotometer with a flame atomisation system, an 1800 lines/mm grating and a wavelength range of 190 to 900 nm. Wavelength accuracy is within ±0.5 nm, six spectral bandwidths from 0.2 to 5.0 nm are available, and the copper detection limit is 0.008 µg/mL or lower.

The double beam system compensates for source, wavelength and electronic drift to give a stable baseline, so hollow cathode lamps need little warm-up. A total reflection optical path increases light throughput, and the gas system uses precision pressure and flow stabilisation for a steady, low-noise flame. The titanium alloy burner is corrosion resistant and needs no water cooling, and quick gas changeover and safety devices support air-acetylene operation.

Built-in data processing covers peak height and area, deuterium lamp background correction and linear and non-linear curve fitting, with an RS232 interface for a PC. The instrument supports flame absorption, flame emission, graphite furnace and hydride generation methods.

Specifications

Technical specifications

17 parameters

Specifications

Model
SP-IAA320
Atomization System
Flame Atomization System
WL range
190-900nm
WL accuracy
≤±0.5nm
WL repeatability
≤0.3nm (single direction)
Spectrum bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution
<40%
Grating
1800 lines/mm
Baseline stability
±0.004Abs/30min
Characteristic concentration
≤0.04μg/ml/1%(Cu)
Detection limit
≤0.008μg/ml(Cu)
Background calibration ability
Greater than 30 times
Output
RS232
Printer
Optional
Power supply
220V 3A, 50Hz
G. W.
138kg (Main instrument)
Package size
1260*800*770mm (Main instrument)
Features

Key features

  • 01

    Double beam stability

    Automatically compensates for light source, wavelength and electronic drift for a stable baseline.

  • 02

    Multiple analysis modes

    Supports flame absorption, flame emission, graphite furnace and hydride generation methods.

  • 03

    Background correction

    Deuterium lamp background correction with a capability greater than 30 times.

  • 04

    Titanium alloy burner

    Corrosion-resistant burner with fast thermal equilibrium and no water cooling required.

  • 05

    Stable gas system

    Precision pressure and flow stabilising devices give a steady, low-noise flame with safety protection.

  • 06

    Built-in data processing

    Peak height and area, curve fitting, on-screen working curves and an RS232 PC interface.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.