STH-ND Series Class N Horizontal Autoclave

Jacketed horizontal Class N autoclaves from 150 L to 400 L with touch screen HMI, F0 value control, built-in printer and electric locking door.

Key specifications

Volume(L)
STH-N150D: 150; STH-N200D: 200; STH-N300D: 300; STH-N400D: 400
Overall Dimensions
STH-N150D: 1260*690*1740; STH-N200D: 1490*690*1740; STH-N300D: 1400*850*1760; STH-N400D: 1680*850*1760
Chamber Size(Ø*L)mm
STH-N150D: φ472*880; STH-N200D: φ472*1150; STH-N300D: φ620*995; STH-N400D: φ620*1320
Steam Consumption (kg)
STH-N150D: ≤13; STH-N200D: ≤15; STH-N300D: ≤20; STH-N400D: ≤25
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The STH-ND series are horizontal Class N autoclaves with a circular inner chamber and jacket structure that provides heat preservation and drying. Four models are offered at 150, 200, 300 and 400 L, working from 115°C to 138°C at 0.23 MPa with a vacuum of -0.086 MPa.

The door uses a disc type embedded gear with an electric lock and pneumatic door seals. The SUS 304 pipeline uses clamp connections for quick assembly, and a standard validation interface is fitted. Control is through an HMI touch screen with microcomputer, offering program selection, parameter setting, report processing and traceability.

Sterilization is assured by both F0 value and temperature and time, with full sterilization records, a built-in printer and USB function. Over-temperature and over-pressure protection are included. The units run on three-phase AC 380 V and need an external compressed air source at 0.4 to 0.7 MPa for the door seal; a compressor of about 40 L can be used if none is available.

Specifications

Technical specifications

17 parameters

USB function

Volume(L)
STH-N150D: 150; STH-N200D: 200; STH-N300D: 300; STH-N400D: 400
Overall Dimensions
STH-N150D: 1260*690*1740; STH-N200D: 1490*690*1740; STH-N300D: 1400*850*1760; STH-N400D: 1680*850*1760
Chamber Size(Ø*L)mm
STH-N150D: φ472*880; STH-N200D: φ472*1150; STH-N300D: φ620*995; STH-N400D: φ620*1320
Steam Consumption (kg)
STH-N150D: ≤13; STH-N200D: ≤15; STH-N300D: ≤20; STH-N400D: ≤25
Water Consumption(kg)
STH-N150D: ≤30; STH-N200D: ≤35; STH-N300D: ≤40; STH-N400D: ≤45
Power(kW)
STH-N150D: ≤18; STH-N200D: ≤23; STH-N300D: ≤23; STH-N400D: ≤23
N.W. / G.W. (kg)
STH-N150D: 390/470; STH-N200D: 435/535; STH-N300D: 540/645; STH-N400D: 630/740

Main Technical Parameter

Design Pressure
-0.1~0.3MPa
Design Temperature
150℃
Working Pressure
0.23MPa
Working Temperature
115~138℃
Temperature Equilibrium
<+2.0℃
Vacuum
-0.086MPa
Water Pressure
0.1-0.2MPa
Compressed Air Pressure
0.4~0.7MPa
Steam Pressure
0.3~0.7MPa
Power Voltage
Three-phase five-wire AC380V/50Hz
Features

Key features

  • 01

    Large chamber range

    150, 200, 300 and 400 L horizontal chambers with jacket structure.

  • 02

    F0 value control

    F0 value and temperature and time together guarantee the sterilization effect.

  • 03

    Touch screen HMI

    Program selection, parameter setting, reports and traceability on a touch screen.

  • 04

    Secure door system

    Disc type embedded gear, electric lock and pneumatic door seals.

  • 05

    Built-in records

    Built-in printer and USB function for complete sterilization records.

  • 06

    Validation interface

    Standard equipment verification interface fitted as standard.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.