Skip to content
Al-Shaker for Scientific and Medical Supplies

STV-III Series Class N Vertical Autoclave with Drying

Vertical Class N steam autoclaves from 35 L to 100 L with drying, 116-134°C sterilization, quick-open hand wheel lid and safety interlock.

Key specifications

Volume
STV-35Ⅲ: 35L; STV-50Ⅲ: 50L; STV-75Ⅲ: 75L; STV-100Ⅲ: 100L
Power
STV-35Ⅲ: 2.5kW; STV-50Ⅲ: 3.5kW; STV-75Ⅲ: 4.5kW; STV-100Ⅲ: 4.5kW
Voltage
AC 220/110V,50/60Hz
Design pressure
0.25MPa
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The STV-III series are microcomputer-controlled vertical Class N autoclaves with a drying function. Four models are available with chamber volumes of 35, 50, 75 and 100 L, built from high quality stainless steel and supplied with stainless steel buckets, with baskets optional.

Sterilization temperature is adjustable from 116°C to 134°C with ±2°C accuracy, at a rated working pressure of 0.22 MPa. Sterilization time is set from 4 to 120 minutes and drying from 0 to 240 minutes. A three-stage temperature rise and fall program raises steam saturation to improve sterilization, cold air is discharged automatically, and steam is exhausted automatically when the cycle ends.

The lid uses a hand wheel translation quick-opening structure with a self-expanding seal and safety interlock. Protection covers over temperature, over pressure, low water level and dry burning. A buzzer sounds at the end of the cycle, a standard test interface is provided, and automatic water inlet and an external printer are optional.

Specifications

Technical specifications

17 parameters

SPECIFICATIONS

Volume
STV-35Ⅲ: 35L; STV-50Ⅲ: 50L; STV-75Ⅲ: 75L; STV-100Ⅲ: 100L
Power
STV-35Ⅲ: 2.5kW; STV-50Ⅲ: 3.5kW; STV-75Ⅲ: 4.5kW; STV-100Ⅲ: 4.5kW
Voltage
AC 220/110V,50/60Hz
Design pressure
0.25MPa
Design temperature
139℃
Rated working pressure
0.22MPa
Rated working temperature
134℃
Sterilization temperature
116℃~134℃
Temperature Accuracy
±2℃
Sterilization time setting range
4~120 min
Drying time setting range
0-240 min
Chamber volume(mm)
STV-35Ⅲ: Ø300*450; STV-50Ⅲ: Ø350*515; STV-75Ⅲ: Ø400*585; STV-100Ⅲ: Ø450*615
Bucket dimension(mm)
STV-35Ⅲ: Ø275*395; STV-50Ⅲ: Ø325*235*2; STV-75Ⅲ: Ø375*265*2; STV-100Ⅲ: Ø425*275*2
Basket dimension(mm)(optional)
STV-35Ⅲ: Ø270*380; STV-50Ⅲ: Ø320*220*2; STV-75Ⅲ: Ø370*250*2; STV-100Ⅲ: Ø420*265*2
Outer dimension(mm)
STV-35Ⅲ: 476*473*990; STV-50Ⅲ: 544*536*1100; STV-75Ⅲ: 586*576*1210; STV-100Ⅲ: 620*610*1275
Package Dimension(W*D*H)(mm)
STV-35Ⅲ: 520*560*1120; STV-50Ⅲ: 580*630*1230; STV-75Ⅲ: 670*620*1350; STV-100Ⅲ: 690*650*1410
N.W. / G.W. (kg)
STV-35Ⅲ: 65/77; STV-50Ⅲ: 82/105; STV-75Ⅲ: 92/117; STV-100Ⅲ: 113/144
Features

Key features

  • 01

    Four chamber sizes

    35, 50, 75 and 100 L models for different laboratory loads.

  • 02

    Built-in drying

    Drying time can be set from 0 to 240 minutes after sterilization.

  • 03

    Improved steam saturation

    Three-stage temperature rise and fall program enhances the sterilization effect.

  • 04

    Quick-opening lid

    Hand wheel translation structure with self-expanding seal and safety interlock.

  • 05

    Automatic air and steam handling

    Cold air is discharged automatically and steam is exhausted at the end of the cycle.

  • 06

    Complete protection

    Over temperature, over pressure, low water level and anti-dry burning protection.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.