DBI-R3000 Thermo Shaker Dry Bath

A heating and shaking dry bath with PID control from 0 to 105°C, 200 to 3000 rpm mixing on a 2 mm orbit and an independently heated lid.

Key specifications

Model
DBI-R3000
Temp. Setting Range
0℃~105℃
Temp. Control Range
RT.+5℃~105℃
Temp. Accuracy
≤±0.3℃*
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The DBI-R3000 is a thermostatic shaker driven by a brushless DC motor, combining dry block heating with mixing for sample incubation, catalysis, blending and preservation. PID control keeps the temperature accurate and adjusts the heating rate to reduce waiting time.

The block is set from 0 to 105°C and controls from room temperature +5°C to 105°C with accuracy and uniformity of ±0.3°C, heating from 25°C to 100°C in 10 min or less. Shaking runs from 200 to 3000 rpm on a 2 mm orbit. The heated lid has its own control up to 110°C to prevent evaporation and cross-contamination, and a built-in fan cools from 100°C to 37°C in 12 min or less.

Ten programs can be stored with up to 5 points and 99 cycles. Short mixing, automatic preheating, auto resume after power failure, temperature calibration and over-heating protection are built in, and optional blocks are available for common tubes and plates. Applications include enzyme reactions and deactivation, PCR sample preparation and storing enzymes or DNA libraries at the bench.

Specifications

Technical specifications

37 parameters

Built-in over-heating protection device, safe and reliable.

Model
DBI-R3000
Temp. Setting Range
0℃~105℃
Temp. Control Range
RT.+5℃~105℃
Temp. Accuracy
≤±0.3℃*
Temp.Uniformity
≤±0.3℃*
Time Range
1sec~99min59sec/1min~99h59min/∞
Display Accuracy
0.1℃
Speed Range
200~3000rpm
Orbit
2mm
Heating Time
≤10min(from 25℃ to 100℃)*
Fan Cooling Time
≤12min(from 100℃ to 37℃)*
Heating Lid Temp. Setting Range
OFF/AUTO/40℃~110℃
Heating Lid Temp. Control Range
RT.+5℃~110℃
Heating Time of Heating Lid
≤10min(from 25℃ to 110℃)*
Heating Lid Independent Temp. Control Function
Yes
Auto Fan Function
Yes
Program Number
10programs(S0~S9)
Multi Point Running
Yes(Max 5points)
Multi cycle
Yes(Max 99times)
Auto Heating
Yes
Auto Constant Temperature at the End of Running
Yes
Heating Lid Mode
Automatic / Manual
Auto Running
Yes
Auto Recovery After Power Failure
Yes
Delay Timing Function
Yes
Power
335W
Electricity
AC220V or AC110V/50-60Hz
Fuse
250V 3A Ф5×20
External Dimension(L*W*H)
296*212*164mm
N.W./G.W.
6.9kg/8kg
Shipping Dimension(L*W*H)
410*350*240mm

Optional blocks

MD30
Capacity: 96×0.2ml PCR Plate; Max. Speed: 2500rpm
MD31
Capacity: 54×0.5ml centrifuge tube; Max. Speed: 2500rpm
MD32
Capacity: 35×1.5ml centrifuge tube; Max. Speed: 2500rpm
MD33
Capacity: 35×2.0ml centrifuge tube; Max. Speed: 2500rpm
MD34
Capacity: 20×1.5ml+15×0.5ml; Max. Speed: 2500rpm
Without Block
Capacity: Elisa plate/Deep-well plate/ Tissue culture plate; Max. Speed: 3000rpm
Features

Key features

  • 01

    Heating with shaking

    200 to 3000 rpm mixing on a 2 mm orbit while incubating.

  • 02

    PID temperature control

    ±0.3°C accuracy and uniformity from room temperature +5°C to 105°C.

  • 03

    Independent heated lid

    Lid control up to 110°C prevents evaporation and cross-contamination.

  • 04

    Fan-assisted cooling

    Built-in fan cools the block from 100°C to 37°C in 12 min or less.

  • 05

    Programmable runs

    10 programs with up to 5 points and 99 cycles.

  • 06

    Brushless DC motor

    Quiet, long-life and maintenance-free drive.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.