Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: ICB-B70E / ICB-B150E / ICB-B250E

BOD Incubator ICB-B Series

Refrigerated BOD incubator in 70, 150 and 250 L sizes, controlling 0 to 65 °C for water analysis, BOD testing and microbial culture.

Key specifications

ICB-B70
ICB-B150 / ICB-B250
Cycle Mode
Forced convection
Function
Temp. Range / 0~65℃
Temp. Resolution Ratio
0.1℃
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The ICB-B Series BOD incubator is a thermostatic unit for water analysis and BOD measurement, culture and preservation of bacteria, molds and other microorganisms, and plant cultivation and breeding experiments. It serves environmental protection, epidemic prevention, drug testing, livestock and aquatic product laboratories.

Three sizes are available, ICB-B70, ICB-B150 and ICB-B250, with a temperature range of 0 to 65 °C and 0.1 °C resolution. Back suction forced convection and an air-cooled hermetic compressor using R134a provide stable control, with intelligent automatic defrosting for frost-free operation. E models offer fixed-value and timed operation with deviation correction and key lock, while non-E models add a 10-segment program.

The mirror stainless steel chamber, tempered glass inner door, magnetic outer door seal, removable shelves, a 43 mm test hole, internal waterproof socket and over-temperature alarm are included.

Specifications

Technical specifications

35 parameters

SPECIFICATIONS

ICB-B70
ICB-B150 / ICB-B250
Cycle Mode
Forced convection
Function
Temp. Range / 0~65℃
Temp. Resolution Ratio
0.1℃
Temp. Motion
High Temp.: ±0.5℃ Low Temp.: ±1℃
Temp. Uniformity
±1.5℃
Structure
Inner Chamber / Mirror Stainless Steel
Outside Material
Cold rolling steel electrostatic spraying exterior
Insulation Layer
Polyurethane
Heater
Stainless steel heater
Power Rating
ICB-B70E: 0.8kW; ICB-B150E: 1.0kW; ICB-B250E: 1.2kW
Compressor
Air-cooled hermetic compressor
Cryogen
R134a
Defrost Structure
Automatic control intelligent defrosting
Test Hole
Inner diameter 43mm(one)
Controlled External Power Supply
Outer universal socket (one), inner waterproof socket(one)
Temp. Setting Mode
Touch button setting
Temp. Display Mode
Measuring temperature: LCD upper screen; setting temperature: the lower row
Timer
E model:0~99.9h Without E model:0~99.9h×10 segment(with timing wait function)
Operation Function
E model:Fixed value operation、timing function, auto stop.
Sensor
PT100
Additional Function
E model:LED light, Deviation correction, Menu key lock, Power failure parameter memory
Safety Device
Over temperature alarm
Specification
Inner Chamber Size(W×L×H)(mm) / 415×350×500 / 490*400*750 / 500*500*950
Exterior Size (W×L×H)(mm)
ICB-B70E: 571×591×1051; ICB-B150E: 646*641*1301; ICB-B250E: 656*741*1501
Packing Size (W×L×H)(mm)
ICB-B70E: 676×680×1235; ICB-B150E: 751*730*1490; ICB-B250E: 761*830*1690
Volume
ICB-B70E: 70L; ICB-B150E: 150L; ICB-B250E: 250L
Load per rack
15kg
Shelf Number
ICB-B70E: 5; ICB-B150E: 9; ICB-B250E: 12
Shelf Space
60mm
Power Supply Current Rating
ICB-B70E: AC220V/2.3A; ICB-B150E: AC220V/3.6A; ICB-B250E: AC220V/5.5A
NW/GW (kg)
ICB-B70E: 69/92; ICB-B150E: 86/114; ICB-B250E: 100/139
Accessory
Shelf / 2
Shelf Frame
4
Optional Accessories
Shelf, touch screen controller, RS485 interface, printer, remote control, USB data storage
Features

Key features

  • 01

    Three chamber sizes

    ICB-B70, ICB-B150 and ICB-B250 models for different sample volumes.

  • 02

    0 to 65 °C control

    PT100 sensing with 0.1 °C resolution and microcomputer control with live LCD display.

  • 03

    Frost-free refrigeration

    Air-cooled hermetic compressor with R134a and intelligent automatic defrost.

  • 04

    Program options

    E models run fixed-value and timed modes; non-E models add a 10-segment temperature program.

  • 05

    Double door design

    Tempered glass inner door for viewing and a magnetically sealed outer door.

  • 06

    Practical extras

    43 mm test hole, internal waterproof socket, external socket and power-failure memory.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.