Key specifications

Capacity (L)
ICB-H103YH: 103; ICB-H152YH: 152; ICB-H253YH: 253; ICB-H412YH: 412; ICB-H722YH: 722; ICB-H1022YH: 1022
Circulation Mode
Forced Convection (Balanced Type)
Dimension (W*D*H), Internal (mm)
ICB-H103YH: 480*390*550; ICB-H152YH: 500*460*660; ICB-H253YH: 640*460*860; ICB-H412YH: 560*530*1390; ICB-H722YH: 980*530*1390; ICB-H1022YH: 980*750*1390
Dimension (W*D*H), External (mm)
ICB-H103YH: 645*700*1255; ICB-H152YH: 665*780*1360; ICB-H253YH: 800*780*1570; ICB-H412YH: 1025*810*1735; ICB-H722YH: 1445*810*1735; ICB-H1022YH: 1445*1030*1735
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The ICB-H-YH Series is a constant temperature and humidity chamber for long-term stability testing of pharmaceuticals and quality assessment in the food, tobacco and cosmetics industries. It is also used for aging and water absorption studies of paints and resins and environmental reliability testing of electronics, automotive parts and metals.

Six models cover 103 to 1022 L, with a temperature range of -5 to 70 °C and humidity from 15 to 95% RH. A frost-free design prevents drift during defrost cycles, and a diffusion-type air duct with a three-speed fan improves uniformity. Programmable fuzzy PID control with 30 segments and 99 cycles sets temperature, humidity, fan speed and ramp rates.

Automatic water replenishment and recycling reduces water use. A wide display with temperature, humidity and water level alarms, over-temperature cut-off, USB data recording and hot gas bypass refrigeration are standard.

Specifications

Technical specifications

17 parameters

Specification

Capacity (L)
ICB-H103YH: 103; ICB-H152YH: 152; ICB-H253YH: 253; ICB-H412YH: 412; ICB-H722YH: 722; ICB-H1022YH: 1022
Circulation Mode
Forced Convection (Balanced Type)
Dimension (W*D*H), Internal (mm)
ICB-H103YH: 480*390*550; ICB-H152YH: 500*460*660; ICB-H253YH: 640*460*860; ICB-H412YH: 560*530*1390; ICB-H722YH: 980*530*1390; ICB-H1022YH: 980*750*1390
Dimension (W*D*H), External (mm)
ICB-H103YH: 645*700*1255; ICB-H152YH: 665*780*1360; ICB-H253YH: 800*780*1570; ICB-H412YH: 1025*810*1735; ICB-H722YH: 1445*810*1735; ICB-H1022YH: 1445*1030*1735
Temperature, Range (℃)
-5~70
Resolution (℃)
0.1
Fluctuation (℃)
±0.2 / ±0.5
Uniformity (℃)
±0.5 / ±1
Humidity
Range / 15%~95%RH
Fluctuation
±1%RH / ±1.5%RH
Operating Ambient Temperature (℃)
5-30
Shelves (Standard)
ICB-H103YH: 2; ICB-H152YH: 3; ICB-H253YH: 3; ICB-H412YH: 4; ICB-H722YH: 4; ICB-H1022YH: 4
Test Hole (mm)
φ40
Electricity, Voltage/Frequency
AC 220V, 50Hz
Consumption (W)
ICB-H103YH: 1300; ICB-H152YH: 1400; ICB-H253YH: 2000; ICB-H412YH: 2500; ICB-H722YH: 3500; ICB-H1022YH: 3800
Safety Protection
Refrigeration System / Compressor overheating, over-current and over-pressure protection; condenser fan overheating protection.
Others
Main power phase sequence and phase loss protection; Leakage and short-circuit protection; Overload protection; Water shortage protection.
Features

Key features

  • 01

    Wide test envelope

    Controls -5 to 70 °C and 15 to 95% RH across six chamber sizes from 103 to 1022 L.

  • 02

    Frost-free stability

    Avoids temperature and humidity drift caused by conventional defrost cycles.

  • 03

    Water-saving humidification

    Automatic replenishment and recycling of water reduces consumption and refilling.

  • 04

    30-segment programs

    Fuzzy PID programs with 30 segments and 99 cycles control ramps, humidity and fan speed.

  • 05

    Alarms on every parameter

    Temperature, humidity and water level alarms with visual and audible prompts.

  • 06

    USB recording

    Connect a printer or USB drive to record data in real time during the test.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.