Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: DM-3005 / DM-3005A / DM-3004

DM Series Digital Density Meter

Oscillating U-tube density meters measuring 0 to 3 g/cm³ from just 2 to 3 mL of sample, with Peltier temperature control, HD camera bubble check and automatic injection.

Key specifications

Beverage Industry
Measuring sugar concentration, food additive indicators , soft drink quality control
Food Industry
Grape juice, tomato juice, fructose syrup, vegetable oil and canned food processing
Brewing Industry
Detection of alcohol concentration of liquor, yellow wine, red wine, beer, fruit wine, rice wine, etc.
Chemical Industry
Chemical urea, detergent, glycol, acid, alkali and polymer density testing
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The DM Series measures liquid density by the oscillating U-tube principle, calculating density from the change in vibration frequency of a small sample in the tube. Three models are offered: the DM-3005 with ±0.0001 g/cm³ accuracy, the DM-3005A at ±0.0003 g/cm³ and the DM-3004 at ±0.0005 g/cm³, all covering 0 to 3 g/cm³. Built-in Peltier control sets the measuring temperature from 5 to 70°C, or 5 to 50°C on the DM-3004.

About 2 to 3 mL of sample is needed. A 1080P HD camera shows the U-tube in real time to confirm there are no bubbles, and a standard peristaltic pump automates injection, measurement and cleaning. Fast and accurate modes, built-in SOPs, atmospheric pressure compensation and a built-in drying pump simplify routine work, with more than 30 units such as specific gravity, alcohol, API and Brix on the DM-3005.

The meters comply with ASTM D4052, D5002, D3505, ISO 12185 and IP 559 and relevant pharmacopoeias. Four user levels, electronic signatures and an optional 21 CFR Part 11 audit trail on the DM-3005 and DM-3005A support regulated laboratories.

Specifications

Technical specifications

40 parameters

INDUSTRY APPLICATIONS

Beverage Industry
Measuring sugar concentration, food additive indicators , soft drink quality control
Food Industry
Grape juice, tomato juice, fructose syrup, vegetable oil and canned food processing
Brewing Industry
Detection of alcohol concentration of liquor, yellow wine, red wine, beer, fruit wine, rice wine, etc.
Chemical Industry
Chemical urea, detergent, glycol, acid, alkali and polymer density testing
Pharmaceutical Industry
Quality control of raw materials and finished products, determination of specific gravity and density (relative density) of pharmaceutical preparations
Petrochemical Industry
Crude oil API index, gasoline, diesel, kerosene density detection, additive mixing ratio process monitoring
Machining
Cleaning agent testing for metal processing, machine manufacturing, automotive industry, and electronic appliances
Flavors and Fragrances
Edible flavors, daily flavors, tobacco flavors, food additives and spices
Testing Agency
Standard laboratories, statutory testing agencies, third-party testing of liquid density measurement

SPECIFICATIONS

Density
DM-3005: 0.00000 g/cm³ to 3.00000 g/cm³; DM-3005A: 0.0000 g/cm³ to 3.0000 g/cm³; DM-3004: 0.0000 g/cm³ to 3.0000 g/cm³
Temperature
DM-3005: 5 ℃ to 70 ℃; DM-3005A: 5 ℃ to 70 ℃; DM-3004: 5 ℃ to 50 ℃
Density
DM-3005: ±0.0001 g/cm³; DM-3005A: ±0.0003 g/cm³; DM-3004: ±0.0005 g/cm³
Temperature
DM-3005: ±0.05 ℃; DM-3005A: ±0.05 ℃; DM-3004: ±0.1 ℃
Density
DM-3005: ±0.00005 g/cm³; DM-3005A: ±0.0001 g/cm³; DM-3004: ±0.0002 g/cm³
Temperature
DM-3005: ±0.02 ℃; DM-3005A: ±0.02 ℃; DM-3004: ±0.05 ℃
Density
DM-3005: 0.00001 g/cm³; DM-3005A: 0.0001 g/cm³; DM-3004: 0.0001 g/cm³
Temperature
0.01 °C
Measuring mode
DM-3005: Density (g/cm³) Density (kg/cm³) 4 ℃ / 20 ℃ / 25 ℃ / Synthermal specific gravity of water More than 30 built-in units such as Density, Specific gravity, Alcohol, API, Brix, Urea, User-defined, etc.; DM-3005A: Density (g/cm³) Density (kg/cm³) 4 ℃ / 20 ℃ / 25 ℃ / Synthermal specific gravity of water User-defined
Injection
Manual / Automatic (peristaltic pump)
Injection check
1080P HD camera, video check, photo check
Calibration
Dry air & Distilled water, Multi-point calibration
Drying pump
Built-in DC air pump, connected to the drying bucket, can provide continuous dry air
Atmospheric pressure compensation
Built-in atmospheric pressure sensor, automatically compensates for atmospheric pressure
User management permissions
DM-3005: Four levels; DM-3005A: Four levels; DM-3004: /
Electronic signature
DM-3005: Yes; DM-3005A: Yes; DM-3004: /
Audit trail
DM-3005: Optional FDA software; DM-3005A: Optional FDA software; DM-3004: /
Report format
PDF / Excel
U-tube
Quartz glass
Minimum sample volume
Approx. 2mL to 3 mL
Temperature control
Peltier (high precision platinum resistance, digital PID regulation, PWM temperature control)
Display
10.1″ color LCD touchscreen
Operating system
Android
Internal storage
128G
User management
DM-3005: 200; DM-3005A: 200; DM-3004: /
Method management
DM-3005: 200; DM-3005A: 200; DM-3004: 100
Test result record
DM-3005: 200,000; DM-3005A: 200,000; DM-3004: 100,000
Communication interfaces
DM-3005: RS232, USB, RJ45; DM-3005A: RS232, USB, RJ45; DM-3004: RS232, USB
Connect PC, LIMS
Yes
Printer (Optional)
DM-3005: Thermal printer Stylus printer Wifi printer; DM-3005A: Thermal printer Stylus printer Wifi printer; DM-3004: Thermal printer Stylus printer
Power supply
AC 100 to 240 V, 50/60 Hz, 120W
Features

Key features

  • 01

    Oscillating U-tube

    Accurate density from 2 to 3 mL of sample, saving valuable material.

  • 02

    Three accuracy levels

    DM-3005, DM-3005A and DM-3004 offer ±0.0001, ±0.0003 and ±0.0005 g/cm³.

  • 03

    HD camera bubble check

    Real-time video of the U-tube confirms bubble-free filling during injection.

  • 04

    Automatic injection

    A peristaltic pump automates injection, measurement and cleaning for higher throughput.

  • 05

    Standards compliance

    Meets ASTM D4052, D5002, D3505, ISO 12185, IP 559 and pharmacopoeia requirements.

  • 06

    Data integrity

    Four user levels, electronic signature and optional 21 CFR Part 11 audit trail.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.