Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: DBI-R100II, DBI-100II

DBI-R100II and DBI-100II Mini Dry Baths

Lightweight mini dry baths under 1 kg with LCD display, USB data saving and interchangeable blocks, available as a heating and cooling model or a heating-only model.

Key specifications

Temperature setting range (℃)
DBI-R100II: 0-100; DBI-100II: 25-100
Temperature range (℃)
DBI-R100II: Room temperature-23~100; DBI-100II: Room temperature+5~100
Temperature control accuracy (℃)
±0.5
Temperature display accuracy (℃)
0.1
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The DBI-R100II and DBI-100II are compact dry block heaters weighing under 1 kg. The DBI-R100II both heats and cools, controlling from room temperature -23°C to 100°C, and includes a hot lid to retain heat. The DBI-100II is a heating model covering room temperature +5°C to 100°C.

Temperature control accuracy is ±0.5°C with 0.1°C display resolution. Heating from 25°C to 100°C takes no more than 20 min, at up to 8°C/min on the DBI-R100II and 6.5°C/min on the DBI-100II. The timer runs from 0 to 999 min or 0 to 999 s, and 9 programs of 2 steps each can be stored.

Optional blocks hold 40 × 0.2 mL, 24 × 0.5 mL, 15 × 1.5 mL, 15 × 2 mL or 6 × 5 mL tubes. Rapid calibration, overheating protection, error code reminders and a USB interface for saving data are standard, and the units run on 12 V DC or a 100 to 240 V adapter.

Specifications

Technical specifications

27 parameters

Specifications

Temperature setting range (℃)
DBI-R100II: 0-100; DBI-100II: 25-100
Temperature range (℃)
DBI-R100II: Room temperature-23~100; DBI-100II: Room temperature+5~100
Temperature control accuracy (℃)
±0.5
Temperature display accuracy (℃)
0.1
Minimum time taken for heating (25℃-100℃)
≤20min
Minimum time for cooling (20℃-10℃)
DBI-R100II: ≤25min; DBI-100II: /
Max. Heating Rate
DBI-R100II: 8℃/min; DBI-100II: 6.5℃/min
Max. Cooling Rate
DBI-R100II: 3℃/min; DBI-100II: /
Time setting range
0-999min/0-999sec
Display
LCD
No. of programs in memory
9 (2 steps for each)
Rapid calibration
Support
USB interface
Support
Error code reminder
Support
External dimension (mm)
110×162×140
Overall weight (kg)
≤1
Power supply
DC12V, AC100V-240V, 50Hz/60Hz
Power (W)
60
Operation temperature (℃)
+10-40
Operation humidity (%RH)
≤80

Optional blocks

18900414
Capacity: 40×0.2 mL; Diameter×depth: 6.4mm×20mm
18900415
Capacity: 24×0.5 mL; Diameter×depth: 8.2mm×28.4mm
18900416
Capacity: 15×1.5 mL; Diameter×depth: 11.2mm×31mm
18900428
Capacity: 15×2 mL; Diameter×depth: 11mm×31mm
18900417
Capacity: 6×5 mL; Diameter×depth: 17mm×31mm
18900426
Capacity: 4×15 mL; Diameter×depth: 16.4mm×45mm
18900427
Capacity: 2×50 mL; Diameter×depth: 29mm×45mm
Features

Key features

  • 01

    Heating and cooling option

    The DBI-R100II controls from room temperature -23°C to 100°C with a hot lid.

  • 02

    Under 1 kg

    Light and compact at 110 × 162 × 140 mm for crowded benches or field use.

  • 03

    Interchangeable blocks

    Blocks for 0.2 mL to 5 mL tubes in 6 to 40 positions.

  • 04

    USB data saving

    A USB interface saves run data.

  • 05

    Program memory

    Stores 9 programs with 2 steps each.

  • 06

    Rapid calibration and protection

    Built-in rapid calibration, overheating protection and error code reminders.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.