Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: BR4-660, BR4-1000

BR4-660 and BR4-1000 Double-Door Blood Bank Refrigerators

Double-door blood bank refrigerators of 658 L and 1008 L holding 4 ± 1°C for up to 576 blood bags, with a standard thermal printer and 72 hour alarm backup.

Key specifications

Specifications
Model: Shelf/drawer; BR4-660: Shelves/12; BR4-1000: Drawers/12
Cooling
Forced -air Cooling
Defrost
Auto
Refrigerant
R134a
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The BR4-660 and BR4-1000 store whole blood, blood components, medicines and bioproducts at a uniform 4 ± 1°C. They offer 658 L and 1008 L of capacity, holding 360 and 576 standard 450 mL blood bags, organized on 12 shelves in the BR4-660 and 12 drawers in the BR4-1000.

Microprocessor-controlled forced-air cooling with electrical heat compensation, SECOP compressors and R134a refrigerant keep the cabinet consistent, while auto-defrost removes moisture from the cooling surface. Separate digital readouts show the upper and lower sections with 0.1°C resolution. Heated, foam-insulated glass doors and acrylic inner doors limit cold loss when a door is opened.

A built-in battery runs the display and alarms for up to 72 hours without power, covering high and low temperature, power failure, abnormal voltage, door ajar and backup battery. A thermal printer is standard, and a safety lock, casters and interior light complete the design for blood banks, hospitals and CDCs.

Specifications

Technical specifications

39 parameters

Caster design and interior light.

Specifications
Model: Shelf/drawer; BR4-660: Shelves/12; BR4-1000: Drawers/12
Cooling
Forced -air Cooling
Defrost
Auto
Refrigerant
R134a
Power consumption(kWh/24h)
6.31 / 8.53
Noise ( db)
51.2 dB(A) / 53.6 dB(A)
Ambient temperature ( ℃)
10~32℃
Temperature range ( ℃)
4±1℃
Cooling system
Model: Compressor brand/QTY; BR4-660: SECOP/1; BR4-1000: SECOP/1
Sensor
NTC
Temperature controller
Microprocessor
Display
Digital display
Power
Model: Voltage/frequency ( V/Hz); BR4-660: 220/50Hz; BR4-1000: 220/50Hz
Power ( W)
364W / 513W
Current ( A)
2.42A / 2.37A
Material
Model: Inside material; BR4-660: 304 Stainless steel; BR4-1000: 304 Stainless steel
Outside material
Color sprayed steel
Insulation
PURF
Size
Model: Capacity ( L/cu.ft); BR4-660: 658/23.23; BR4-1000: 1008/35.59
Bloodbags(450ml)
360 / 576
N W ./G W . ( kg)
202/257 / 265/335
Exterior size(W × D × H)(mm)
1220×640×1885 / 1240×860×1895
Interior size(W × D × H)(mm)
1100×454×1325 / 1100×684×1325
Package size(W × D × H)(mm)
1330×740×2120 / 1325×970×2130
CBM
2.09 / 2.74
20GP/40GP/40HQ
12/27/27 / 8/18/18
Alarm
Model: High/low temperature; BR4-660: Y; BR4-1000: Y
Power off
Y
Temperature controller malfunction
Y
Backup battery malfunction
Y
Ambient temperature
10~32℃
Power failure backup system(alarm)
72h
Accessories
Model: Caster; BR4-660: Y; BR4-1000: Y
Outer door/Type
2/Heating & Foam glass door
Inner door
6
Test hole
1/25MM
Thermal p rinter
Y
Light
LED
Temperature recorder
Optional chart recorder
Features

Key features

  • 01

    Uniform 4 ± 1°C storage

    Forced-air cooling with electrical heat compensation maintains a consistent cabinet temperature.

  • 02

    Two capacities

    658 L and 1008 L models hold 360 and 576 blood bags of 450 mL.

  • 03

    Dual-zone display

    Upper and lower chamber temperatures are shown separately with 0.1°C resolution.

  • 04

    72 hour alarm backup

    A built-in battery keeps the display and five alarm conditions active during power loss.

  • 05

    Built-in thermal printer

    Temperature records can be printed directly for blood bank documentation.

  • 06

    Acrylic inner doors

    Inner doors reduce cold loss from the rest of the cabinet when one door is opened.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team