Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: DBI-110

DBI-110 Four-Zone Dry Bath Incubator

A dry bath incubator with four blocks timed independently in groups A to D, heating from room temperature +5°C to 110°C under a transparent splash lid.

Key specifications

Model
DBI-110
Temp. setting range
0°C ~110°C
Temp. control range
RT+5°C ~110°C
Timing range
1min ~ 99h59min/∞
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The DBI-110 is a microprocessor-controlled dry block heating system that replaces a traditional water bath. It is widely used for sample preservation, DNA amplification reactions, electrophoresis, denaturation, solidification and thermostatic incubation of serum and biochemical samples.

Temperature is set from 0 to 110°C and controlled from room temperature +5°C to 110°C, with accuracy and uniformity of ±0.3°C at 37°C and 0.1°C display resolution. Heating from 25°C to 110°C takes 20 min or less. Four block positions in groups A, B, C and D can each be timed independently or together, from 1 min to 99 h 59 min or continuously.

A blue transparent lid prevents samples splashing out. Optional blocks cover common tubes from 6 mm to 28 mm diameter as well as plates, and custom blocks are available. Automatic preheating, automatic running, auto resume after power failure, built-in calibration and over-heating protection are included.

Specifications

Technical specifications

27 parameters

Built-in over-heating protection device, safe and reliable.

Model
DBI-110
Temp. setting range
0°C ~110°C
Temp. control range
RT+5°C ~110°C
Timing range
1min ~ 99h59min/∞
Temp. accuracy
≤±0.3°C@37°C
Display accuracy
0.1°C
Temp. uniformity
≤±0.3°C@37°C
Heating time
≤20min(from 25°C~110°C)
Auto heating
Yes
Auto running
Yes
Auto resume to run
Yes
Timing independently for each group
Yes
Block quantity
4
Power
500W
Electricity
110V or 220V AC /50-60Hz
Fuse
250V 3A Ф5×20
Dimension (mm) (W*D*H)
254x370x228
Net weight (Kg)
8

Optional Blocks:

MD01
Tube Diameter: 6mm; Capacity: 48; Model: MD10; Diameter: 26mm; Capacity: 8
MD02
Tube Diameter: 7mm; Capacity: 48; Model: MD11; Diameter: 28mm; Capacity: 4
MD03
Tube Diameter: 10mm; Capacity: 24; Model: MD12; Diameter: 40mm; Capacity: 3
MD04
Tube Diameter: 12mm; Capacity: 24; Model: MD13; Diameter: 0.2ml centrifuge tube; Capacity: 48
MD05
Tube Diameter: 13mm; Capacity: 24; Model: MD14; Diameter: 0.5ml centrifuge tube; Capacity: 48
MD06
Tube Diameter: 15mm; Capacity: 16; Model: MD15; Diameter: 1.5ml centrifuge tube; Capacity: 24
MD07
Tube Diameter: 16mm; Capacity: 16; Model: MD16; Diameter: 2.0ml centrifuge tube; Capacity: 24
MD08
Tube Diameter: 19mm; Capacity: 12; Model: MD17; Diameter: 0.2ml PCR plate; Capacity: 96
MD09
Tube Diameter: 20mm; Capacity: 12; Model: MD18; Diameter: 0.2ml Elisa plate; Capacity: 96
Features

Key features

  • 01

    Four timed groups

    Groups A, B, C and D are timed independently or simultaneously.

  • 02

    Up to 110°C

    Controls from room temperature +5°C to 110°C with ±0.3°C accuracy.

  • 03

    Transparent splash lid

    A blue transparent lid keeps samples from splashing out.

  • 04

    Wide block choice

    Blocks for tubes from 6 to 28 mm in diameter and plates, with custom blocks on request.

  • 05

    Built-in safeguards

    Auto resume after power failure, calibration function and over-heating protection.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.