Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: MPR-A200 / MPR-A200HT

MPR-A200HT / MPR-A200 Monochromator ELISA Microplate Reader

Monochromator-based absorbance microplate reader for 96 and 384-well plates, covering 200 to 1000 nm in 1 nm steps; the MPR-A200HT adds a cuvette port.

Key specifications

Cuvette Mode
MPR-A200: NO; MPR-A200HT: YES
Microplate Type
96/384 wells
Detection Mode
Absorbance
Light Source
Xenon flash lamp/number of flashes>10 9
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The MPR-A200 and MPR-A200HT are absorbance microplate readers based on a grating monochromator and xenon flash lamp, covering 200 to 1000 nm in 1 nm steps for spectral scanning, endpoint and kinetic assays. They read 96 and 384-well plates with or without lids over 0 to 4.0 OD, with a double beam reference channel for stable data and automatic calibration of the lamp, grating, detector and plate position at start-up.

At 450 nm, linearity is R² ≥ 0.999 from 0 to 3.0 Abs and accuracy is ±(1.0% + 0.003 Abs) up to 2.0 Abs. A 96-well plate is read in under 8 seconds in fast mode, with linear shaking at three speeds and incubation from room temperature +4 °C to 45 °C. The MPR-A200HT adds an independent cuvette slot with its own incubation.

A 10-inch Android touch screen with 16 GB storage allows standalone use, with user permission levels, a standard curve library, FTP transfer and multiple report formats. An optional u-Nano plate quantifies 1 to 16 nucleic acid or protein samples from 2 to 4 µL without dilution.

Specifications

Technical specifications

28 parameters

Specifications

Cuvette Mode
MPR-A200: NO; MPR-A200HT: YES
Microplate Type
96/384 wells
Detection Mode
Absorbance
Light Source
Xenon flash lamp/number of flashes>10 9
Wavelength Range
200~1000nm
Wavelength Accuracy
2nm
Wavelength Repeatability
0.2nm
Optical System
Monochromator, 1nm step
Reading Range
0~4.0OD
Bandwidth
<2.5nm
Detection System
2 silicon photodetectors, one for measurement, one for reference
Linear @450nm
R 2 ≥0.999, [0.0-3.0 Abs]
Absorbance Accuracy @450nm
± (1.0 % + 0.003 Abs), (0 ~2.0 Abs]; ± 2.0 %, (2.0 ~ 2.5 Abs]
Absorbance Repeatability @450nm
CV<0.5 % or SD<0.003 accurate mode; CV<1.0% fast mode
Measuring Speed
96-well plate: fast mode <8 seconds, accurate mode <28 seconds (end point method)
Shaking
Linear, 3 speeds adjustable
Temperature Range
RT.+4 °C~45 °C
Temp. Accuracy & Uniformity
±0.5 °C @37 °C, ±0.5 °C @37 °C
User Interface
Built-in software, independent use
Optional
Readerlt-II software, u-Nano Ultra-Micro Plate, ABS Optical Performance Validation Board
Operation Display
Touch screen input, Android system, 10-inch LCD display full board information, can be connected with keyboard and mouse
Internal Storage
16 G storage, can store more than 20,000 data files
Port
1 type B USB interface, 2 type A USB interfaces, 1 network port
Robotic Arm Compatibility
Temporarily incompatible
Electricity
DC 24 V, 6.67 A
External Dimension(W*D*H)
300*500*260 mm
N.W./G.W.
15.5kg/21kg
Package Dimension(W*D*H)
690*490*500mm
Features

Key features

  • 01

    Free wavelength choice

    Grating monochromator selects any wavelength from 200 to 1000 nm in 1 nm steps.

  • 02

    Double beam reference

    A reference detector channel stabilises readings, with automatic calibration at start-up.

  • 03

    Fast plate reading

    96-well endpoint reads in under 8 seconds in fast mode and under 28 seconds in accurate mode.

  • 04

    Incubation and shaking

    Temperature control to 45 °C with three-speed linear shaking.

  • 05

    Cuvette mode

    The MPR-A200HT adds a separate cuvette slot for endpoint, kinetic and scan measurements.

  • 06

    Standalone software

    10-inch Android touch screen with user levels, curve library and report export.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.