Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: FTA406

Semi-Automatic Fat Analyzer FTA406

Semi-automatic Soxhlet-type fat analyzer processing six samples per batch, with heating up to 280°C and solvent recovery of 80% or more.

Key specifications

Model
FTA406
Temperature range
Room temperature+5℃~ 280℃
Measuring range
0 ~ 100%
Temperature accuracy
±1℃
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The FTA406 is a semi-automatic fat analyzer based on Soxhlet extraction, measuring fat content from 0 to 100% in samples of 0.5 to 15 g (typically 2 to 5 g). It processes six samples per batch using 80 mL solvent cups.

Integral metal heating covers room temperature +5°C to 280°C with ±1°C accuracy, and the electric circuit is isolated from the extraction space for safety. Extraction time is shortened by 20 to 80% compared with conventional methods, and solvent recovery is at least 80%. An air insulation design keeps the case near room temperature.

A 4.3-inch LCD with microcomputer control shows set and actual temperature together with set and elapsed time. Timer functions, over-temperature alarms and sound, light and on-screen prompts are included, and linear bearings give smooth lifting of the extraction assembly.

Specifications

Technical specifications

13 parameters

Specifications

Model
FTA406
Temperature range
Room temperature+5℃~ 280℃
Measuring range
0 ~ 100%
Temperature accuracy
±1℃
Sample weight
0.5 ~ 15g(generally 2 ~ 5g,depending on sample)
Capacity per batch
6pcs/batch
Solvent cup volume
80mL
Solvent recovery
≥80%
Shortened extraction time
20 ~ 80%
Power supply
220VAC±10%, 50Hz
Power
1KW
Dimensions
650mm×320mm×715mm
Net Weight
35Kg
Features

Key features

  • 01

    Six samples per batch

    Processes six samples at a time with 80 mL solvent cups.

  • 02

    Wide temperature range

    Integral metal heating from room temperature +5°C to 280°C with ±1°C accuracy.

  • 03

    Solvent recovery

    Recovers at least 80% of solvent and shortens extraction time by 20 to 80%.

  • 04

    Isolated circuit

    Electric circuit is separated from the extraction space for safe operation.

  • 05

    Triple alarms

    Sound, light and LCD text prompts for over-temperature and timer events.

  • 06

    Smooth lifting

    Linear bearing lifting mechanism for easy, steady operation.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.