Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: FBA800

Fiber Analyzer FBA800

Six-position fiber analyzer for crude fiber, NDF, ADF, hemicellulose and ADL, using integrated infrared heating and a 7-inch touch screen.

Key specifications

Model
FBA800
Measurement range
0.1% ~ 100%
Sample weight
0.5g ~ 3g
Repeatability error
Crude Fiber Content < 10%, ≤0.4% Crude Fiber Content ≥10%, ≤1%
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The FBA800 is a fiber analyzer that determines crude fiber, neutral detergent fiber (NDF), acid detergent fiber (ADF), hemicellulose and acid detergent lignin (ADL). It measures from 0.1% to 100% on samples of 0.5 to 3 g, six samples per batch.

Integrated infrared heating warms the crucibles quickly and evenly for consistent extraction, and heating power can be adjusted to control the heating rate and reduce energy use. A built-in preheating function shortens the run, reaching preheat in 10 to 12 minutes and boiling in 13 to 15 minutes. Repeatability error is 0.4% or less below 10% crude fiber and 1% or less above.

The hidden pull-out solution barrel makes dosing easier, corrosive liquids never touch a pump body, and overflow protection prevents spills from operator error. A crucible backflush function stops samples from caking during filtration. Five crucible specifications are supplied as standard, and the 7-inch touch screen offers count-up and countdown timing.

Specifications

Technical specifications

11 parameters

the accuracy of test results.

Model
FBA800
Measurement range
0.1% ~ 100%
Sample weight
0.5g ~ 3g
Repeatability error
Crude Fiber Content < 10%, ≤0.4% Crude Fiber Content ≥10%, ≤1%
Capacity
6 pcs/batch
Pre-heating time
10-12min
Heating to boiling
13-15min
Display
7 inches touch color screen
Rated power
2.2KW
Power supply
220 VAC ±10% 50Hz
Dimension
776mm×476mm×644mm
Features

Key features

  • 01

    Five fiber fractions

    Determines crude fiber, NDF, ADF, hemicellulose and ADL.

  • 02

    Infrared heating

    Integrated infrared heating for fast, uniform crucible heating and consistent extraction.

  • 03

    Built-in preheating

    Preheats in 10 to 12 minutes to shorten total experiment time.

  • 04

    Corrosion-safe fluid path

    Corrosive liquid does not contact any pump body, protecting the drain pump.

  • 05

    Overflow protection

    Dosing overflow protection prevents corrosive liquid spills from operator error.

  • 06

    Crucible backflush

    Backflush function prevents samples caking in the crucible during filtration.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.