Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: FLUOM-100

Fluorometer FLUOM-100

Dual-channel benchtop fluorometer quantifying nucleic acids and proteins from 1 to 20 μL samples in 3 seconds, with sensitivity down to 0.5 pg/μL dsDNA.

Key specifications

Model
FLUOM-100
Sample Capacity
1
Sample Volume
1-20μL
Tube Type
0.5ml PCR tube
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The FLUOM-100 is a fluorometer based on fluorescence assay technology, using the principle that fluorescence intensity is proportional to concentration at low concentrations to analyze samples qualitatively and quantitatively. It measures nucleic acids (dsDNA, oligo, RNA, microRNA), proteins, hormones, drugs, microorganisms and other low concentration bioactive compounds.

Samples of 1 to 20 μL are read in 0.5 mL PCR tubes in 3 seconds. Two channels, with excitation at 470 and 625 nm and emission at 525 and 690 nm, detect two fluorescence types simultaneously. The response range spans five orders of magnitude with linearity of R² ≥ 0.995, repeatability below 1.5% and sensitivity down to 0.5 pg/μL dsDNA. Calibration uses 2 or 3 points, and the instrument works with most reagents.

A 7-inch color touch screen keeps operation simple, and up to 10000 records can be stored and exported by USB drive or printer in CSV or PDF format.

Specifications

Technical specifications

25 parameters

Specifications

Model
FLUOM-100
Sample Capacity
1
Sample Volume
1-20μL
Tube Type
0.5ml PCR tube
Channel Number
2
Measurement Time
3s
Repeatability
<1.5%
Calibration Method
2 or 3 point calibration
Response Range
Five orders of magnitude
Linearity
R 2 ≥ 0.995
Excitation Wavelength
470/625 (standard)
Emission Wavelength
525/690(standard)
Concentration Range
dsDNA HS: 0.005ng/μL~120ng/μL, dsDNA BR: 0.2ng/μL~2000ng/μL, Oligo: 0.01ng/μL~240ng/μL, RNA: 0.2ng/μL~200ng/μL, MicroRNA: 0.025ng/μL~150ng/μL, Protein: 12.5μg/mL~5mg/mL Protein BR: 0.1mg/mL~20mg/mL
Sensitivity
0.5pg/μL dsDNA
Light Source
Monochrome LED
Detector
Photodiode
Display
Touch screen display
Programs Stored
10000
Data Export
U Disk
Data Format
CSV PDF
Data Interface
USB (Type A)*2, USB (Type B)*1
Power Adapter
100-240V@50-60Hz
Voltage
DC12V 2A
Power
4.5W
Net Weight
1kg
Features

Key features

  • 01

    3-second reading

    Sample concentration measured in 3 seconds.

  • 02

    Dual channels

    Excitation at 470 and 625 nm for two fluorescence types simultaneously.

  • 03

    High sensitivity

    Minimum detection of 0.5 pg/μL dsDNA.

  • 04

    Wide response range

    Five orders of magnitude with R² ≥ 0.995 linearity.

  • 05

    Open reagent use

    Works with most fluorescence reagents.

  • 06

    Data storage

    Stores 10000 records, exported by USB drive or printer.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.