Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: BA-A-120

Fully Automatic Biochemistry Analyzer BA-A-120

Random access chemistry analyzer running a constant 120 tests per hour with single or double reagents, with 80 cooled reagent positions and 40 sample positions.

Key specifications

Machine type
Random access, open reagent & locked reagent (optional)
Test speed
Constant 120 tests/hour (Mono reagent or double reagent)
Test principle
Colorimetric method, turbidimetry
Test method
1 point end, 2 point end, Fixed-Time, Kinetics
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The BA-A-120 is a fully automatic biochemistry analyzer for measuring cholesterol, glucose, enzymes, proteins and other parameters in samples such as blood or urine. It is a random access system that runs a constant 120 tests per hour with mono or double reagents, using colorimetric and turbidimetric methods with end point, fixed time and kinetic assays.

The reagent tray has 80 positions (40 for R1 and 40 for R2) cooled around the clock at 2 to 14°C by a Peltier system, and the system is open to any reagent. The sample tray holds 40 positions for micro cups or tubes. A ceramic syringe dispenses as little as 0.1 μL, and 50 optical plastic cuvettes run reactions from 150 μL at 37 ±0.1°C.

The probe has liquid level sensing, collision protection and inside and outside washing, and a Teflon-coated mixer reduces carry-over. A fully closed optical system measures multiple wavelengths at once. The software supports automatic dilution, linear and nonlinear calibration with up to 8 points, Westgard and L-J quality control, and an optional barcode reader.

Specifications

Technical specifications

32 parameters

SPECIFICATIONS

Machine type
Random access, open reagent & locked reagent (optional)
Test speed
Constant 120 tests/hour (Mono reagent or double reagent)
Test principle
Colorimetric method, turbidimetry
Test method
1 point end, 2 point end, Fixed-Time, Kinetics
Calibration type
Linear & nonlinear
Sample tray
40 sample positions
Sample tube
Micro cup & test tube & blood collection tube can be used. (Φ 12 -13 )mm *(25-100 )mm
Sample volume
2-30uL step by 0.1uL
Sample probe
Liquid surface detection, timely tracking for liquid volume. Collision avoidance
Sample barcode
Sample barcode reader (optional)
Reagent tray
80 reagent positions (40 for Rl & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14°C, open system, could accept any reagent
Reagent volume
20-300uL, step by luL
Reagent needle
Liquid surface detection, timely tracking for liquid volume. Collision avoidance
Regent barcode
Regent barcode reader (optional)
Reaction tray
50 reaction cuvettes, new amorphous optical plastics reaction cups, perfect transmittance.
Reaction volume
150uL-330uL
Reaction time
10 minutes
Temperature
Peltier pad incubation system, reaction temperature (37°C ±0.1 °C)
Mixer
paddle-type mixing, effective reducing of carry-over
Light source
Halogen lamp
Wavelength
340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm;700nm(4 more options)
Absorbance range
0-4.0 Abs
Resolution
0.0001 Abs
Operation system
Windows XP, Windows 7, Windows 8, Windows 10
Data processing
Automatic calibration, test combination, effective time management of reagents, serum index, whole process detection, linear expansion of enzyme, blank deduction,dirty cuvette memory, cross infection prevention, patient information memory and association input, automatic report audit, data fuzzy query, report statistics and printing, reference range grading, alarm information classification, user
Report printing
6 formats optional, support custom pattern
interface
TCP/IP network interface
Power supply
AC 110/220V ± 10%, 50/60 Hz, 650W
Water consumption
6L/hour(maximum)
Dimension
750mm*550mm *490mm(L*W*H)
Weight
70kg
language
All languages
Features

Key features

  • 01

    120 tests per hour

    Constant throughput with mono or double reagents in random access mode.

  • 02

    Cooled reagent tray

    80 reagent positions kept at 2 to 14°C around the clock by a Peltier system.

  • 03

    Precision dispensing

    Ceramic syringe with permanent piston dispensing as low as 0.1 μL.

  • 04

    Smart sampling probe

    Liquid level sensing, collision protection and inside and outside probe washing.

  • 05

    Low reaction volume

    50 cuvettes with reaction volume from 150 μL at 37 ±0.1°C.

  • 06

    Calibration and QC

    Up to 8-point linear and nonlinear calibration with Westgard and L-J quality control.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.