Reference: GC-900A

GC-900A Gas Chromatograph

Gas chromatograph with touchscreen control, an optimized injection system, column oven up to 450°C and support for up to 4 detectors including FID and TCD.

Key specifications

Host
: Pressure/Flow Control; GC-900A: Mechanical control
Number of sample ports supported
3
Maximum number of detectors supported
4
Temperature Control System
8-channel independent temperature control system
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The GC-900A gas chromatograph uses an optimized sample injection system to improve the accuracy and reproducibility of analysis, and an upgraded circuit system for faster computation, better data processing and long-term stability. It is operated through an interactive touchscreen.

The column oven runs from room temperature +5°C to 450°C with 0.01°C steps, heating at up to 120°C/min and cooling from 450°C to 50°C in under 5 minutes, with at least 20 program ramp steps. An 8-channel independent temperature control system supports up to 3 injection ports and 4 detectors. Compatible inlets include split/splitless capillary, packed column, cold on-column, PTV, valve, headspace and thermal desorption injection.

The FID offers a detection limit of ≤4.3 pg C/s and a linear range of ≥10^7 with auto-ignition, and the TCD a sensitivity of ≥8000 mV·mL/mg. An independent split cold trap and septum purge trap are fitted. The GC-900A suits petrochemical, environmental, food and pharmaceutical testing.

Specifications

Technical specifications

26 parameters

Specification

Host
: Pressure/Flow Control; GC-900A: Mechanical control
Number of sample ports supported
3
Maximum number of detectors supported
4
Temperature Control System
8-channel independent temperature control system
Column oven
: Control temperature; GC-900A: Room temperature+5℃-450℃
Minimum step value
0.01℃
Maximum heating rate
120℃/min
Cooling time
From 450°C to 50°C in <5 minutes
Programmed Temperature Ramp
≥20 steps
Temperature Stability
Ambient temperature ±1°C, column oven temperature variation <0.01°C
Others
1. Automatic Furnace Temperature Protection Function
Injection System
: Injection type; GC-900A: Compatible with split/splitless capillary injectors, septum purging packed column injectors, cold column head injectors, programmable temperature vaporization injection ports, valve injection systems, headspace injection systems, thermal desorption injection systems, etc.
Maximum operating temperature
450℃
Programmatic current increase
≥ 20 steps
Others
Features an independent split cold trap and a septum purge trap
Detector
Hydrogen Flame Ionization Detector (FID) / Maximum operating temperature / 450℃
Detection limit
≤4.3 pg C/s ( n-hexadecane )
Baseline drift (30 min)
≤2×10⁻ 13 A
Baseline noise
≤2×10 ⁻ 14 A
Dynamic Linear Range
≥10⁷
Function
Auto-ignition function
Thermal Conductivity Detector (TCD)
: Sensitivity; GC-900A: ≥8000mV.mL/mg
Baseline drift (30 min)
≤0.2mV
Baseline noise
≤0.05mV
Dynamic Linear Range
≥10 5
Function
Air Gap Flow Protection Function
Features

Key features

  • 01

    Touchscreen control

    Smart interactive touchscreen for setup and operation.

  • 02

    Fast column oven

    Up to 450°C, heating at 120°C/min and cooling to 50°C in under 5 minutes.

  • 03

    Flexible injection

    Split/splitless, packed, cold on-column, PTV, valve, headspace and thermal desorption inlets.

  • 04

    Up to 4 detectors

    Supports 3 injection ports and 4 detectors with 8-channel temperature control.

  • 05

    Sensitive FID and TCD

    FID detection limit ≤4.3 pg C/s with auto-ignition; TCD sensitivity ≥8000 mV·mL/mg.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.