Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: HAD-BT40

HAD-BT40 Bluetooth Water Hardness Tester

Bluetooth water hardness tester with a solid state sensor that works with an Android smartphone or tablet, offering 2 to 5 point calibration and ±1% F.S. accuracy.

Key specifications

Model
HAD-BT40
Range (Concentration)
0.05 to 200mmol/L
Range (German Degree)
0 to 1122°dH
Range (English Degree)
0 to 1404°e
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The HAD-BT40 is a Bluetooth water hardness tester fitted with a solid state sensor and operated from an Android smartphone or tablet. It measures 0.05 to 200 mmol/L, equivalent to 0 to 20000 mg/L as CaCO3, with ±1% F.S. accuracy, and also reads mV within ±2000.0 mV.

Hardness can be shown in °dH, °e, °fH, gpg, mg/L or mmol/L. Calibration uses 2 to 5 points from standards of 0.01, 0.1, 1, 10 and 100 mmol/L, and manual temperature compensation covers 0 to 50°C. Auto-read locks the endpoint, timed interval readings send data to memory or a printer, and a limit alarm warns when results leave a set range.

A calibration due alarm, calibration report and six-digit password protection support quality control. Bluetooth conductivity and dissolved oxygen testers can connect to the same device at the same time for multiparameter monitoring of process and drinking water.

Specifications

Technical specifications

29 parameters

Specifications

Model
HAD-BT40
Range (Concentration)
0.05 to 200mmol/L
Range (German Degree)
0 to 1122°dH
Range (English Degree)
0 to 1404°e
Range (French Degree)
0 to 2000°fH
Range (Grains per gallon)
0 to 1170gpg
Range (CaCO 3 )
0 to 20000mg/L
Range (CaO)
0 to 11220mg/L
Range (Ca 2+ )
0 to 8020mg/L
Resolution
0.001, 0.01, 0.1, 1
Accuracy
±1% F.S.
Calibration Points
2 to 5 points
Calibration Solutions
0.01, 0.1, 1, 10, 100mmol/L
Range
±2000.0mV
Resolution
0.1, 1mV, selectable
Accuracy
±0.2mV
Temperature Compensation
0 to 50°C/32 to 122°F, manual
Stability Criteria
Fast, standard, slow
Measurement Modes
Continuous or auto-read
Timed Interval Readings
10, 30, 60, 300 seconds or off
Calibration Due Alarm
1 to 99 days or off
Data Transfer
Send to memory or printer
Password Protection
6 digits
Connectivity
Bluetooth 4.0 or later
Max Wireless Range
10m/32.8ft
Power
2×1.2V lithium batteries or AAA batteries
Dimensions
175(L)×40(Dia.)mm
Package Dimension
300(W)×100(D)×250(H)mm
G.W./N.W.
1kg/0.1kg
Features

Key features

  • 01

    Smartphone operation

    Connects over Bluetooth to an Android smartphone or tablet for display and setup.

  • 02

    Six hardness units

    Reports in °dH, °e, °fH, gpg, mg/L and mmol/L.

  • 03

    2 to 5 point calibration

    Uses standards from 0.01 to 100 mmol/L, with a calibration report of date, points and slopes.

  • 04

    Alarms and timed readings

    Limit alarm, calibration due alarm and timed interval readings to memory or printer.

  • 05

    Multiparameter setup

    Bluetooth conductivity and dissolved oxygen testers can connect to the same device simultaneously.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.