Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: BOD-806A

BOD-806A BOD Analyzer

Six-sample BOD analyzer using the differential pressure method, measuring 0 to 2000 mg/L over 1 to 30 day incubations with live BOD display.

Key specifications

Model
BOD-806A
Measuring range
0-2000mg/L
Measurement error
Meet the water quality BOD 5 precision test standard (Glucose-glutamic acid standard solution BOD 5 = 180-230mg/l)
Measurement days
1 —-30 days
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The BOD-806A measures biochemical oxygen demand using the differential pressure method, which simulates the natural biodegradation of organic matter. In each sealed culture bottle, oxygen in the air above the sample replaces the dissolved oxygen consumed as organic matter breaks down, while the CO2 produced is removed. The resulting pressure change is monitored to calculate the BOD value.

The analyzer tests up to six water samples at the same time in 580 mL culture bottles, with incubation times of 1 to 30 days at 20±1°C and a measuring range of 0 to 2000 mg/L. Recording intervals range from 24 minutes to 12 hours, and accuracy meets the BOD5 precision test using the glucose-glutamic acid standard.

The current BOD value is shown on screen throughout the test and can be viewed at any time, and 20 groups of BOD5 results are stored automatically. With a rated power of 10 W, it is suited to wastewater, environmental and water treatment laboratories.

Specifications

Technical specifications

14 parameters

Store BOD5 results for 20 groups.

Model
BOD-806A
Measuring range
0-2000mg/L
Measurement error
Meet the water quality BOD 5 precision test standard (Glucose-glutamic acid standard solution BOD 5 = 180-230mg/l)
Measurement days
1 —-30 days
Measurement quantity
≤ 6
Recording interval
24 minutes ~12 hours/time
Storage quantity
20groups BOD 5 result value
Culture bottle volume
580ml
Incubation temperature
20±1°C
Working power
AC power 110–220V, 50/60Hz
Rated power
10W
Size
272*185*75mm
Package Dimension (W*D*H)
450*390*510mm
G.W./N.W.
9.2Kg/2.4Kg
Features

Key features

  • 01

    Differential pressure method

    Calculates BOD from pressure change in sealed bottles, simulating natural biodegradation.

  • 02

    Six samples at once

    Runs up to six culture bottles of 580 mL simultaneously.

  • 03

    1 to 30 day tests

    Flexible incubation time with recording every 24 minutes to 12 hours.

  • 04

    Live BOD display

    Current BOD value is shown on screen during the test.

  • 05

    Automatic storage

    Stores 20 groups of BOD5 results for later review.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.