Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: HPLC-2025

HPLC-2025 High Performance Liquid Chromatograph

Modular HPLC system with isocratic, binary or quaternary pumps up to 62 MPa, a 108-vial autosampler and UV detection from 190 to 800 nm.

Key specifications

Flow Rate Range
0.001mL/min~10.000mL/min
Pump Type
Isocratic(P1), Binary(P2), Quaternary(P4)
Maximum Pressure
62MPa
Plunger Rinsing
Supported
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The HPLC-2025 is a modular high performance liquid chromatograph built for reliability, precision and ease of use. The HPLC-2025P1, P2 and P4 pumps provide isocratic, binary or quaternary delivery from 0.001 to 10.000 mL/min at up to 62 MPa. A reciprocating tandem plunger design with a pressure dynamic suppression algorithm gives precise gradients and retention time repeatability below 0.2%.

The pump cam is machined from high-hardness alloy steel above 55 HRC, with a high-power motor, NSK bearings and a suspended floating plunger that resists seal wear. Online automatic plunger rinsing prevents buffer salt crystallization, and purging is available from both the workstation and the panel. The autosampler holds 108 × 2 mL vials or 96 and 384-well plates, injects 0 to 100 μL in low-loss, microliter pick-up or full-loop modes, and has 0.003% carryover, with optional 4 to 40°C sample cooling.

The column oven reaches up to 85°C, and the detector uses deuterium and tungsten lamps over 190 to 800 nm with ±1 nm wavelength accuracy. Online degassing is optional. The system serves pharmaceutical, food, environmental and research analysis.

Specifications

Technical specifications

35 parameters

Specification

Flow Rate Range
0.001mL/min~10.000mL/min
Pump Type
Isocratic(P1), Binary(P2), Quaternary(P4)
Maximum Pressure
62MPa
Plunger Rinsing
Supported
Sample Capacity
108, 2mL(96&384 well plates)
Injection Range
0-100μL
Injection Mode
Low-loss, microliter carrying, full-loop
Injection Time
Minimum to 5 s
Carryover
0.003%
Degassing Unit
Online degassing(optional)
Temperature Control
4-40 ℃(optional)
Operating Principle
Peltier element and fan-based forced air
Temperature Range
5 ℃ above ambient to 85 ℃ 10 ℃ below ambient to 85 ℃
Light Source
Deuterium(transmission type) and Tungsten lamp
Wavelength Range
190-800nm
Wavelength Accuracy
+/- 1nm
Wavelength Precision
+/- 0.1nm
Linearity
>2.5 AU
Wavelength Calibration
Mercury lamp
Light Source
Deuterium (transmission type) & Tungsten lamp
Wavelength Range
190~800nm
Slit Width
1nm, 2nm, 4nm, 8nm
Wavelength Accuracy
+/- 1nm
Wavelength Precision
+/- 0.1nm
Linearity
> 2.0 AU
Wavelength Calibration
Holmium glass
Light Source
150W Xe lamp
Wavelength Range(Excitation)
200 to 850nm Zero order
Wavelength Range(Emission)
250 to 900nm Zero order
Detection Sensitivity (Raman peak of water S/N)
S/N ≥ 900 (Baseline method)
Wavelength Accuracy
±3nm
Wavelength Repeatability
±0.5nm
Noise
≤0.05mV(1.0mL/min 100% Methanol, Gain 1.00)
Drift
≤0.3mV/30 min(1.0mL/min 100% Methanol, Gain 1.00)
Min. Detection Limit
≤5.0×10-6 g/mL(500pg)
Features

Key features

  • 01

    Isocratic, binary or quaternary

    P1, P2 and P4 pumps deliver 0.001 to 10.000 mL/min at up to 62 MPa.

  • 02

    Retention time repeatability

    Tandem plunger design and pressure dynamic suppression give under 0.2% repeatability.

  • 03

    Durable pump mechanics

    Hardened alloy cam, NSK bearings and floating plunger extend service life.

  • 04

    Automatic plunger rinsing

    Periodic online rinsing prevents buffer salt crystallization and microbial growth.

  • 05

    High-capacity autosampler

    108 vials or 96/384-well plates, 0 to 100 μL injection and 0.003% carryover.

  • 06

    190 to 800 nm detection

    Deuterium and tungsten lamps with ±1 nm wavelength accuracy.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.