Skip to content
Al-Shaker for Scientific and Medical Supplies

Moisture Content Tester MCA110-T Series

110 g halogen moisture tester in three readability versions down to 0.001 g, with a 5 inch color touch screen, real-time curve and three heating modes.

Key specifications

Heating Time Setting
Stop Mode Setting: Baud Rate Setting; Heating Temp. Setting: Language (CN/EN) Setting
Date & Time Setting
Stop Mode Setting: Data Storage Setting; Heating Temp. Setting: Factory Reset
Instrument Calibration
Stop Mode Setting: Empty Pan Preheating
Max. Capacity
110g
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The MCA110-T Series moisture content tester provides convenient, precise moisture analysis for applications that need routine moisture detection. All models have a 110 g capacity and a 100 mm pan, with readability of 0.01 g (MCA110-T10E), 0.005 g (MCA110-T5E) or 0.001 g (MCA110-T1E) and matching moisture readability of 0.10, 0.05 or 0.01%.

A halogen lamp with PT100 temperature sensing heats from 40 to 160 °C in 1 °C steps, with test times from 1 to 99 min. Standard, fast and soft heating modes and automatic, manual or timed stop modes suit different samples, and empty pan preheating is available.

The 5 inch full-color touch screen displays a real-time test curve. A silent rapid cooling fan, adaptive micro-voltage adjustment, clock function, history query of 20 stored groups and 11 configurable settings, including calibration and baud rate, are included.

Specifications

Technical specifications

24 parameters

11 Function Settings

Heating Time Setting
Stop Mode Setting: Baud Rate Setting; Heating Temp. Setting: Language (CN/EN) Setting
Date & Time Setting
Stop Mode Setting: Data Storage Setting; Heating Temp. Setting: Factory Reset
Instrument Calibration
Stop Mode Setting: Empty Pan Preheating

Specification

Max. Capacity
110g
Readability
MCA110-T10E: 0.01g; MCA110-T5E: 0.005g; MCA110-T1E: 0.001g
Sensor
Load cell
Pan Size
φ100mm
Display
5-inch full-color touch screen
Operating Temperature
15℃~30℃
Heat Source
Halogen lamp
Temp. Sensor
PT100
Temp. Range
40°C~160°C (1°C step)
Time Setting
1~99min (10s step)
Moisture Range
0.00%~100.00%
Moisture Readability
MCA110-T10E: 0.10%; MCA110-T5E: 0.05%; MCA110-T1E: 0.01%
Solid Content Range
100.00%~0.00%
Solid Content Readability
MCA110-T10E: 0.10%; MCA110-T5E: 0.05%; MCA110-T1E: 0.01%
Data Storage
20 Groups
Real-time Curve
Real-time dynamic curve
Testing Space
30mm
Electricity
220V, 50Hz / 110V, 60Hz
External Dimensions
340*215*170mm
Package Dimensions
415*310*255mm
N.W./G.W.
4.0kg/3.5kg
Features

Key features

  • 01

    Three readability options

    0.01 g, 0.005 g or 0.001 g readability with moisture readout down to 0.01%.

  • 02

    Halogen heating

    Heats from 40 to 160 °C in 1 °C steps with PT100 temperature sensing.

  • 03

    Three heating modes

    Standard, fast and soft modes plus automatic, manual and timed stop.

  • 04

    Color touch screen

    5 inch full-color display with a real-time dynamic test curve.

  • 05

    Rapid cooling

    Silent fan cools the chamber quickly between tests.

  • 06

    Records and settings

    Stores 20 result groups with clock, history query and 11 function settings.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.