Reference: SP-LIF450

SP-LIF450 NIR Spectrophotometer

Near-infrared spectrophotometer covering 900 to 2500 nm for non-destructive analysis of moisture, fat, protein and amino acids in about one minute.

Key specifications

Model
SP-LIF450
Measurement Modes
Diffuse reflection sample cell
Wavelength Range(nm)
900~2500
Spectral Bandwidth(nm)
12
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SP-LIF450 is a near-infrared spectrophotometer covering 900 to 2500 nm with a cooled Hamamatsu InGaAs detector, ±0.2 nm wavelength accuracy and 12 nm spectral bandwidth. Samples are analysed by diffuse reflection without chemical reagents, pre-treatment or destruction, and several components such as moisture, fat, protein and amino acids can be determined within about one minute.

An integrating sphere diffuse reflection system with a large sampling spot and rotating sample table improves reproducibility for uneven samples. A built-in PTFE reference and polystyrene wavelength standard provide automatic reference correction and wavelength monitoring, and instruments are calibrated with NIST-traceable standards so models can be transferred between units. Calibration uses MPLS regression.

Sample cups and accessories cover particles, powders, liquids and films. The software includes data collection, preprocessing, evaluation and user management, and ambient temperature and humidity are recorded with each spectrum.

Specifications

Technical specifications

18 parameters

SPECIFICATIONS

Model
SP-LIF450
Measurement Modes
Diffuse reflection sample cell
Wavelength Range(nm)
900~2500
Spectral Bandwidth(nm)
12
Wavelength Accuracy(nm)
±0.2
Wavelength Repeatability(nm)
≤0.05
Stray Light(%)
≤0.1
Absorbance Noise(Abs)
≤0.0005
Analysis Time
1min(adjustable)
Detector
Japan hamamatsu cooled InGaAs
Output
USB2.0
Calibration Technology
MPLS Modified least squares regression calibration technology
Ambient Temperature (℃)
5~35
Ambient Humidity (%RH)
5~85
Instrument Dimension(W*D*H)(mm)
540*380*220
Package Dimension (W*D*H)(mm)
800*680*580
Power Supply
90~250V\50Hz (or 60Hz)
N.W./G.W.)(kg)
18/55
Features

Key features

  • 01

    No sample preparation

    Direct diffuse reflection measurement with no reagents, pre-treatment or sample destruction.

  • 02

    Multi-component analysis

    Determines moisture, fat, protein and amino acids together within about one minute.

  • 03

    Integrating sphere and rotating table

    A large sampling spot and rotating table improve reproducibility for uneven samples.

  • 04

    Automatic reference correction

    Built-in PTFE reference and polystyrene standard for automatic reference and wavelength checks.

  • 05

    Model transfer

    Each instrument is calibrated with NIST-traceable standards so calibration models transfer between units.

  • 06

    Ambient monitoring

    Temperature and humidity are logged in each spectrum file to help optimise measurement conditions.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.