NEC100-R24M Nitrogen Evaporator / Sample Concentrator

A 24-position nitrogen evaporator that combines software-controlled gas flow, liquid-level tracking needles and a heated sample rack for fast, uniform concentration of small-volume samples.

Key specifications

Model
NEC100-R24M
Concentration
Nitrogen blowing and sample rack heating
Nitrogen Channel
Max.4 channels; Every channel has own switch valve, can be controlled individually based on the number of concentration samples.
Sample Capacity
24 position
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The NEC100-R24M concentrates high-throughput, small-volume samples by blowing nitrogen onto each vial while the sample rack is heated from room temperature to 100°C. It holds 24 positions and accepts 2 mL and 5 mL centrifuge vials and 2 mL GC vials, and the reserved rack space also suits 1.5 mL vials and 1 to 2 mL QuEChERS tubes.

Gas is distributed over up to 4 channels, each with its own valve, and the flow rate is set in software from 0 to 3.0 L/min in 0.1 L/min steps, independent of how many channels are open. The needles descend at a controlled 0 to 100.0 mm/min to follow the liquid level over a travel of up to 50 mm.

All parameters are set and stored on a built-in 7-inch touch screen. Typical uses include sample preparation for chromatographic analysis and QuEChERS workflows.

Specifications

Technical specifications

17 parameters

Specification

Model
NEC100-R24M
Concentration
Nitrogen blowing and sample rack heating
Nitrogen Channel
Max.4 channels; Every channel has own switch valve, can be controlled individually based on the number of concentration samples.
Sample Capacity
24 position
Sample Vials
2mL/5mL centrifuge vials, 2mL GC vial
Range of Gas Flow Rate
0 ~3.0L/min, precise to 0.1L/min
Temperature Range of Sample Rack
RT.~100°C, precise to 0.1°C
Software Interface
7-inch built-in touch screen
Fume Hood/Ventilation
Required
Hollow Sample Heating Rack
Observe the sample clearly
Safety
Alarm reminder for temperature and pressure, cut off the gas flow automatically
Storage Environment
Temperature: 0~40°C; Humidity: 20%~85%
Operating Environment
Temperature: 10~40°C; Humidity: 20%~80%
Electricity
200~240V, 50/60Hz
Power Rate
1000W
External Dimension
470*250*430mm
Net Weight
21kg
Features

Key features

  • 01

    Liquid-level tracking needles

    Nitrogen needles move down at a set speed in manual or auto mode, with up to 50 mm of vertical travel for vials of different heights.

  • 02

    Software-set flow rate

    Gas flow is set from 0 to 3.0 L/min in 0.1 L/min steps and stays constant regardless of how many channels are switched on.

  • 03

    Four switchable channels

    Each of the 4 nitrogen channels has its own valve, so unused rows can be closed to save gas.

  • 04

    Heated hollow sample rack

    The rack heats from room temperature to 100°C in 0.1°C steps, and its hollow design lets the operator see the samples.

  • 05

    7-inch touch screen control

    Temperature, flow and needle speed are set on the built-in screen, and methods can be saved and recalled.

  • 06

    Automatic safety cut-off

    Temperature and pressure alarms cut off the gas flow automatically when a fault is detected.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.