Stepper-driven peristaltic pump delivering 0.169 to 1880 mL/min at 0.1 to 400 rpm, with timed, copy and volume dispensing and ±0.5% repeatability.

Key specifications

RPM
0.1-400rpm / Dispensing time / 0.1-999.9S / Using tubing / 15#、24#、35#、36#
Speed resolution
0.1rpm(≤100rpm) 1rpm(>100rpm) / Dispensing volume / 400μL-9999L / Flow range / 0.169-1880mL/min
Filling volume resolution
0.001-0.01mL (Different according to the tubing) / Times / 0-9999 (0 Infinite loop) / Tubing wall / 2.4mm / Roller seal / Yes
Repeat error
±0.5% / Intervals / 0.1-999.9s / Pressure adjust / No / Factory pressure / 0.15Mpa
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The PP-Z400 drive with PH-Z1880 pump head is a peristaltic pump for transfer and dispensing, running at 0.1 to 400 rpm for flow rates of 0.169 to 1880 mL/min with 15#, 24#, 35# and 36# tubing. A dual-CPU design separates drive and control, and one-key filling gives repeatability of ±0.5%.

Three dispensing modes are available: timed, copy and volume dispense, covering 400 µL to 9999 L with dispensing times of 0.1 to 999.9 s and a suck-back angle adjustable up to 720 degrees. Flow can be calibrated, and the pump supports start, stop, reverse and full-speed purge. A 3.5-inch LCD shows all parameters, and external control includes 4-20 mA, 0-10K, TTL start/stop and direction, RS232 and RS485, plus foot switch and sensor inputs.

The housing is PPS, the four rollers are 304 stainless steel and gaskets are PTFE. It suits small and medium dose filling in pharmaceutical, food, chemical, biological, laboratory and environmental applications.

Specifications

Technical specifications

15 parameters

Specifications

RPM
0.1-400rpm / Dispensing time / 0.1-999.9S / Using tubing / 15#、24#、35#、36#
Speed resolution
0.1rpm(≤100rpm) 1rpm(>100rpm) / Dispensing volume / 400μL-9999L / Flow range / 0.169-1880mL/min
Filling volume resolution
0.001-0.01mL (Different according to the tubing) / Times / 0-9999 (0 Infinite loop) / Tubing wall / 2.4mm / Roller seal / Yes
Repeat error
±0.5% / Intervals / 0.1-999.9s / Pressure adjust / No / Factory pressure / 0.15Mpa
Retention error
100rpm,1% within 68 hours (Filling special tube) / Suction angle / 0-720° / Shell material / PPS
Display
LCD screen (3.5 inch) / Protection level / IP31 / Roller material / SS
Operation
Membrane keypad +Digital control knob / Power / ≤45W / Roller No. / 4
Working environment
Temperature, 0℃ to 40℃ Relative humidity < 80% / Weight / 6.8kg / Product No. / 2022503
External speed control
0-5V (optional)、0-10V (optional)、4-20mA (standard), 0-10K (standard)
Type of external control
Start /stop, Direction change TTL 5V (standard), TTL 12V (optional), TTL 24V (optional)
Port output
DC12V Power Output; DC5V TTL Output (optional)
Communication Interface
RS232, RS485 (Start/stop, Direction change, speed control)
Power supply
AC220V±10%, 50Hz/60Hz(standard); AC110V±10%, 50Hz/60Hz; AC380V±10%, 50Hz/60Hz(optional)
Package Dimension (W*D*H)(mm)
390*340*280
G.W.(kg)
8
Features

Key features

  • 01

    Wide flow range

    0.169 to 1880 mL/min at 0.1 to 400 rpm, depending on tubing size.

  • 02

    Three dispensing modes

    Timed, copy and volume dispensing from 400 µL to 9999 L with adjustable suck-back up to 720 degrees.

  • 03

    Dual-CPU control

    Separate drive and control processors give one-key filling with ±0.5% repeatability.

  • 04

    Remote and automated control

    4-20 mA and 0-10K speed control, TTL start/stop and direction, RS232 and RS485 communication.

  • 05

    Robust materials

    PPS housing, 304 stainless steel rollers and PTFE gaskets.

  • 06

    Power-off memory

    Settings are retained after power loss, and a coated circuit board improves interference resistance.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.