TOC-M2000 and TOC-M5000 Total Organic Carbon Analyzers

High temperature combustion TOC analyzers with an NDIR detector, measuring TC, TIC, TOC and NPOC from 0 to 1000 mg/L with 680°C platinum catalytic oxidation.

Key specifications

Detector
NDIR
Parameters
TC, TIC, TOC, NPOC
Digestion Mode
High Temperature Combustion
Operation Mode
PC software Control
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The TOC-M2000 and TOC-M5000 are total organic carbon analyzers that use high temperature combustion with 680°C catalytic oxidation over a platinum catalyst, a method well suited to seawater samples. An NDIR detector gives high sensitivity and stability for TC, TIC, TOC and NPOC.

The measuring range is 0 to 1000 mg/L, extendable to 100,000 mg/L by manual dilution, with detection limits of 50 μg/L for TC and 20 μg/L for IC and repeatability of ≤3%. A TC measurement takes around 4 minutes and IC around 3 minutes. The TOC-M5000 adds automatic sample dilution, acid addition and gas purging. Precise gas flow control, PID temperature control and three-stage dehydration support accurate results.

Both models are operated from PC software with standard curve management and consumables reminders, and their modular design simplifies maintenance. An optional autosampler handles liquid samples, and a solid sample module is available for solids. Typical uses include drinking water, wastewater, pharmaceutical water and environmental monitoring.

Specifications

Technical specifications

13 parameters

Specifications

Detector
NDIR
Parameters
TC, TIC, TOC, NPOC
Digestion Mode
High Temperature Combustion
Operation Mode
PC software Control
Application
Liquid sample (AS-W20 is optional.) Solid sample ( AS-S200 is needed.)
Gas Requirement
Oxygen ≥ 99.995%
Measurement Range
0-1000mg/L, can extend to 0-100,000mg/L(manually dilution)
Detection Limit
TC: 50μg/L IC: 20μg/L
Measuring Time
TC: around 4min IC: around 3min
Max. Permissible Error
TOC: ± 5% IC: ± 4%
Repeatability
≤3%
Injection Volume
TC: 100-500μL IC: 100-2000μL
Power
AC110/220V, 50/60Hz, 700W
Features

Key features

  • 01

    680°C catalytic combustion

    Platinum catalyst oxidation suited to difficult matrices such as seawater.

  • 02

    NDIR detection

    High sensitivity and stability, with TC detection limit of 50 μg/L.

  • 03

    Four parameters

    Measures TC, TIC, TOC and NPOC from 0 to 1000 mg/L.

  • 04

    Automatic sample handling

    TOC-M5000 performs auto dilution, acid addition and gas purging.

  • 05

    Three-stage dehydration

    Improves drying efficiency and measurement stability.

  • 06

    PC software control

    Standard curve management, consumables reminders and optional autosampler.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team