Reference: SP-601-F

Ultra-Micro Spectrophotometer SP-601-F

Full-wavelength microvolume spectrophotometer measuring nucleic acids, proteins and OD600 from 0.5 to 2 μL samples, with a fluorescence channel and cuvette mode.

Key specifications

Model
SP-601-F
Detection Function
Nucleic Acid / Fluorescence / OD600
Volume
0.5–2 μL
Dimensions (L*W*H)
318*210*188 mm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SP-601-F is a full-wavelength micro-spectrophotometer covering 190 to 850 nm for fast quantification of nucleic acids, proteins and cell suspensions. A cuvette mode measures the concentration of bacterial cultures (OD600), and a fluorescence detection function is also included.

Only 0.5 to 2 μL of sample is needed, and it can be recovered after measurement. A xenon flash lamp and a 2048-pixel linear CCD give wavelength accuracy of ±1 nm and spectral resolution of 3 nm or better. Optical paths of 0.03, 0.05, 0.1, 0.2 and 1 mm are set by a high-precision motor with 0.001 mm accuracy, extending the dsDNA range from 2 to 37500 ng/μL, and detection takes under 6 seconds. Contaminants such as EDTA, phenol, protein, guanidine salts and RNA are flagged.

A 7-inch capacitive multi-touch screen and automatic detection keep the workflow simple. Applications include clinical diagnostics, blood analysis, forensic identification, environmental microbiology, food safety and molecular biology research.

Specifications

Technical specifications

36 parameters

Specifications

Model
SP-601-F
Detection Function
Nucleic Acid / Fluorescence / OD600
Volume
0.5–2 μL
Dimensions (L*W*H)
318*210*188 mm
Weight
4.85 kg
Optical Path
0.03 mm, 0.05 mm, 0.1 mm, 0.2 mm, 1 mm
Light Source
Xenon flash lamp/number of flashes>10 9
Detector Type
2048 pixel linear array CCD
Wavelength Range
190–850 nm
Wavelength Accuracy
±1 nm
Spectral Resolution
≤ 3 nm (FWHM @ Hg 253.7 nm)
Absorbance Precision
0.002Abs (1 mm optical path)
Absorbance Accuracy
±1% (7.332Abs absorbance @ 260nm)
Absorbance Range
0.04-750 (at 260 nm wavelength, equivalent to 10 mm optical path)
Concentration Range
2 ng/μL dsDNA-37500 ng/μL dsDNA
Contaminant Detection
EDTA, GTC, Phenol, Protein, Guanidine salts, RNA
Detection Time
< 6 s
Light Source
Single color LED
Absorbance Range
0-4.000 Abs
Repeatability
(0, 3) ≤ 0.5%, (3, 4) ≤ 1 .5%
Absorbance Accuracy
(0, 2) ≤ 0.005A, (2, 3) ≤ 1%, (3, 4) ≤ 2%
Heating Temperature
37 °C ± 0.5 °C
Stirring Speed
12 adjustable speeds, 100-1200 rpm
Sample Volume
≥ 50 μL (0.5 mL PCR tube)
Detection Time
4 s
Detection Channels
2 channels
Repeatability
< 1.5%
Stability
< 1.5%
Linearity
R 2 ≥ 0.995
Light Source
Single color LED
Excitation Wavelength
470 nm, 624 nm
Emission Wavelength
525 nm, 692 nm
Printing/Interface
Built-in thermal printer, USB 2.0 × 2
Data Export Formats
xls, csv, txt, jpg, png
Experimental Data
>10,000
Power Supply
DC 12V 5A, 60W
Features

Key features

  • 01

    Microvolume samples

    Requires only 0.5 to 2 μL, recoverable after measurement.

  • 02

    Full spectrum

    190 to 850 nm with ±1 nm wavelength accuracy and a 2048-pixel CCD.

  • 03

    Wide concentration range

    dsDNA from 2 to 37500 ng/μL using five optical path lengths.

  • 04

    Three detection modes

    Nucleic acid and protein, fluorescence, and OD600 cuvette measurement.

  • 05

    Contaminant detection

    Flags EDTA, GTC, phenol, protein, guanidine salts and RNA.

  • 06

    7-inch touch screen

    Capacitive multi-touch interface with automatic detection.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.