SP-LUV7600 Double Beam UV-Vis Spectrophotometer

Double beam UV-Vis spectrophotometer covering 190 to 1100 nm with continuously variable 0.5 to 6 nm bandwidth and stray light of 0.03% or less.

Key specifications

Model
SP-LUV7600
Optical system
Double-beam System
Monochromator system
Czerny-Turner monochromator
Wavelength range
190nm~1100nm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The SP-LUV7600 is a double beam UV-Vis spectrophotometer with a Czerny-Turner monochromator and 1200 lines/mm grating, covering 190 to 1100 nm. Spectral bandwidth is continuously variable from 0.5 to 6 nm in 0.1 nm steps, wavelength accuracy is ±0.3 nm and stray light is 0.03% or less, which suits high absorbance samples.

Real-time digital ratio feedback in the double beam optics offsets source drift for a stable baseline, and built-in characteristic wavelengths are used for automatic wavelength checking and correction. The Hamamatsu long-life deuterium lamp is rated for more than 2000 hours, and both lamps can be replaced without removing the housing or realigning the optics.

A 7-inch colour touch screen runs wavelength scans, time scans, multi-wavelength and quantitative analysis and stores methods, with USB-A and USB-B outputs for data transfer.

Specifications

Technical specifications

27 parameters

Specifications

Model
SP-LUV7600
Optical system
Double-beam System
Monochromator system
Czerny-Turner monochromator
Wavelength range
190nm~1100nm
Wavelength accuracy
±0.3nm
Wavelength reproducibility
≤0.1nm
Spectral bandwidth
0.5~6.0nm
Photometric accuracy
±0.002Abs(0~0.5Abs)、±0.004Abs(0.5~1.0Abs)、±0.3%T(0~100%T)
Photometric reproducibility
≤0.001Abs(0~0.5Abs)、≤0.002Abs(0.5~1.0Abs)、≤0.1%T(0~100%T)
Photometric range
-0.00~200.0(%T) -4.0~4.0(A)
Stray light
≤0.03%T(220nm,NaI;360nm,NaNO 2 )
Baseline flatness
±0.0008A
Baseline stability
≤0.0005Abs/h
Noise
≤0.1%T(100%T),≤0.05%T(0%T),≤±0.0005A/h(500nm,0Abs,2nm bandwidth)
Baseline Dark Noise
±0.1%T
Scaning speed
High / medium / low / very low
WL scan interval
0.05/0.1/0.2/0.5/1/2 nm
Grating
1200 lines / mm
Detector
Photocell
Display
7-inch large-screen color touch LCD screen
Light source
Hamamatsu long-life deuterium lamp and long-life halogen tungsten lamp
Photometric Mode
T/A/Energy
Output
USB-A/USB-B
Power
AC90V~250V, 50H/ 60Hz
N.W./G.W.(kg)
24/50
Instrument Dimension (W*D*H)(mm)
600*470*220
Package Dimension (W*D*H) (mm)
800*670*570
Features

Key features

  • 01

    Variable spectral bandwidth

    Bandwidth adjusts from 0.5 to 6 nm in 0.1 nm steps to match resolution to the analysis.

  • 02

    Ultra-low stray light

    Czerny-Turner optics keep stray light at 0.03% or less for high absorbance measurements.

  • 03

    Stable double beam baseline

    Real-time digital ratio feedback offsets source drift, with baseline stability of 0.0005 Abs/h or better.

  • 04

    Automatic wavelength correction

    Built-in characteristic wavelengths verify and correct accuracy to ±0.3 nm.

  • 05

    Easy lamp replacement

    Hamamatsu deuterium lamp rated over 2000 hours, replaceable without opening the housing or optical adjustment.

  • 06

    7-inch touch screen

    Runs wavelength, time, multi-wavelength and quantitative modes with method storage and USB output.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.