Skip to content
Al-Shaker for Scientific and Medical Supplies

FLTZ Single-Channel Chillers (-100 to 90 °C)

High-precision single-loop chillers for semiconductor process and test equipment, across six ranges from 5 to 90 °C down to -100 to 90 °C, with ±0.1 °C accuracy.

Key specifications

Temperature range (family)
-100 to 90 (sub-ranges 5 to 90, -25 to 90, -45 to 90, -80 to 90, -100 to 90, 15 to 25) °C
Temperature control accuracy
±0.1 (customizable to ±0.01) °C
Cooling capacity at 10 °C, 5 to 90 °C models
6 / 8 / 10 / 15 / 20 / 25 / 40 kW
Cooling capacity at -15 °C, -25 to 90 °C models
2 / 3 / 3.8 / 6 / 7.6 / 10 / 15 kW
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

FLTZ single-channel chillers control one fluid loop with a PID algorithm, magnetic-drive pump and electronic expansion valve, holding ±0.1 °C (customizable to ±0.01 °C). LNEYA offers them as process chillers (5 to 90 °C, 6 to 40 kW), thermal chillers (-25 to 90 °C), low-temperature chillers (-45 to 90 °C), recirculating water chillers (-80 to 90 °C, 0.6 to 3 kW) and recirculation chillers (-100 to 90 °C), plus a 15 to 25 °C variant.

Water-cooled models carry a W suffix, and compressor hot gas provides heating without a heater below about 40 °C. Typical uses are wafer processing, packaging and test equipment where temperature stability affects yield.

Specifications

Technical specifications

9 parameters

Performance

Temperature range (family)
-100 to 90 (sub-ranges 5 to 90, -25 to 90, -45 to 90, -80 to 90, -100 to 90, 15 to 25) °C
Temperature control accuracy
±0.1 (customizable to ±0.01) °C
Cooling capacity at 10 °C, 5 to 90 °C models
6 / 8 / 10 / 15 / 20 / 25 / 40 kW
Cooling capacity at -15 °C, -25 to 90 °C models
2 / 3 / 3.8 / 6 / 7.6 / 10 / 15 kW
Cooling capacity at -35 °C, -45 to 90 °C models
1 / 1.4 / 1.8 / 2.5 / 3.3 / 5 / 8 kW
Cooling capacity at -70 °C, -80 to 90 °C models
0.6 / 1 / 1.5 / 2 / 3 kW

Hydraulics

Internal circulating fluid volume
4 to 20 L

Physical

Refrigerant
R410A / R448A / R404A (by range)
Heat transfer media
Silicone oil, fluorinated liquid, glycol-water solution, DI water (above 10 °C)
Features

Key features

  • 01

    Six temperature ranges

    From 5 to 90 °C down to -100 to 90 °C.

  • 02

    ±0.1 °C accuracy

    Customizable to ±0.01 °C.

  • 03

    Compact single loop

    Single inlet and outlet keep circuits independent.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.