Skip to content
Al-Shaker for Scientific and Medical Supplies
LNEYA logo

Our manufacturers

LNEYA

LNEYA temperature control from China: LT recirculating chillers, SUNDI heating/cooling circulators, high-temperature heating circulators, and TCU reactor control.

Products in our catalog
59
Industries served
4
Country of origin
China

About LNEYA

Through Al-Shaker

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

LNEYA is a Chinese temperature-control manufacturer. The catalogue Al-Shaker specifies is four process lines: LT recirculating chillers (−80 to 30 °C, ±0.5 °C, MODBUS RTU RS485), SUNDI heating/cooling circulators (−25 to +200 °C, extendable to +300 °C), high-temperature heating circulators (+10 to +300 °C, UC 7-inch touchscreen), and TCU reactor control (−120 to 250 °C on 5–60 reactors).

kW band, pump flow, and reactor count are options on those lines. Al-Shaker specifies the family and the first duty, then installs, trains, and supports the system across Jordan, the GCC, and MENA.

The range

LNEYA instruments we supply

Recirculating chillers LT

Recirculating chillers LT

LNEYA LT recirculating chillers: −80 to 30 °C, ±0.5 °C; LT 10–30 °C cooling 3–14 kW at 15 °C; pump 30 L/min at 1.6 bar; MODBUS RTU RS485.

View product

SUNDI heating/cooling circulators

SUNDI heating/cooling circulators

LNEYA SUNDI circulators: −25 to +200 °C (extendable −25 to +300), ±0.5 °C medium, cooling 1.8–200 kW, heating 3.5–200 kW, pump 35–600 L/min.

View product

High-temperature heating circulators

High-temperature heating circulators

LNEYA high-temperature heating circulators: +10 to +300 °C, ±0.5 °C (custom ±0.1), heating 5.5–130 kW; UC 50–300 °C with a 7-inch touchscreen.

View product

TCU reactor temperature control

TCU reactor temperature control

LNEYA TCU for reactors: −120 to 250 °C, 5–60 reactors, ±0.5 °C; SR electric heat 25–80 kW; pump 200–750 L/min at 2.5 bar.

View product

LT2 Cooling Circulator (-25 to 30 °C)

LT2 Cooling Circulator (-25 to 30 °C)

Recirculating chiller series reaching -25 °C with ±0.5 °C accuracy and 1.5 to 5 kW of cooling capacity at -15 °C, in air- or water-cooled versions.

View product

LTZ Glycol Chiller (5 to 90 °C)

LTZ Glycol Chiller (5 to 90 °C)

Heating-and-cooling glycol chiller for 5 to 90 °C with ±0.3 °C accuracy, 4 to 20 kW cooling and 3.5 to 15 kW built-in heating.

View product

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.