Skip to content
Al-Shaker for Scientific and Medical Supplies

LTZ Ultra-Low Temperature Chillers (-115 to -30 °C)

Variable-frequency LTZ chillers for deep-cold process cooling in three ranges: -60 to -30, -80 to -50 and -115 to -80 °C, each offered air- or water-cooled.

Key specifications

Temperature range, air-cooled series
-60 to -30 °C
Temperature range, water-cooled series
-80 to -50 °C
Temperature range, cryogenic series
-115 to -80 °C
Cooling capacity, -60 to -30 °C range
4.9 to 93.2 kW
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

These LTZ ranges extend LNEYA's variable-frequency chillers into ultra-low temperatures: -60 to -30 °C (4.9 to 93.2 kW), -80 to -50 °C (3.7 to 78.5 kW) and -115 to -80 °C (0.6 to 2.8 kW). Accuracy is ±0.3 °C on the published tables.

All ranges are available in air-cooled and water-cooled versions with a 7-inch touch screen, Excel data export, self-diagnosis and overload protection. LNEYA presents them for extraction, reactors, semiconductor and battery testing; its dedicated cryogenic page also describes -150 °C direct-cooled designs.

Specifications

Technical specifications

9 parameters

Performance

Temperature range, air-cooled series
-60 to -30 °C
Temperature range, water-cooled series
-80 to -50 °C
Temperature range, cryogenic series
-115 to -80 °C
Cooling capacity, -60 to -30 °C range
4.9 to 93.2 kW
Cooling capacity, -80 to -50 °C range
3.7 to 78.5 kW
Cooling capacity, -115 to -80 °C range
0.6 to 2.8 kW
Temperature control accuracy
±0.3 to ±0.5 °C

Control

Operation panel
7-inch color touch screen, curve recording, Excel export
Communication
MODBUS RTU, RS485
Features

Key features

  • 01

    Three deep-cold ranges

    -60 to -30, -80 to -50 and -115 to -80 °C.

  • 02

    Air or water cooled

    Each temperature range is available in both versions.

  • 03

    Data logging

    Touch screen records curves and exports Excel files.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.