Skip to content
Al-Shaker for Scientific and Medical Supplies

GD Battery Test Chamber (-40 to 100 °C)

Standard battery test chambers combining a temperature chamber with an antifreeze flow and pressure loop, -40 to 100 °C with ±0.1 °C antifreeze accuracy.

Key specifications

Temperature range
-40 to 100 °C
Antifreeze temperature control accuracy
±0.1 °C
Chamber temperature uniformity
≤ ±1 (unloaded) °C
Antifreeze flow control
1 to 40 / 1 to 25 / 1 to 10 L/min, ±0.2 L/min
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

These chambers simulate temperature, flow rate and pressure conditions for power-battery samples during performance, safety and life-cycle testing. The GD-9000 models have independent upper and lower chambers; the GD-1000 has a single 100 x 100 x 100 cm cavity. They pair with a KRYCH antifreeze loop with 1 to 40 L/min flow control at ±0.2 L/min.

Chamber uniformity is within ±1 °C unloaded, cooling is possible directly from 100 °C and a variable-frequency compressor saves over 20% energy. Safety features include explosion-proof chains and pressure relief on the door, a fully welded stainless steel door, SUS304 inner chamber and 100 mm insulation. Data can be acquired and exported.

Specifications

Technical specifications

8 parameters

Performance

Temperature range
-40 to 100 °C
Antifreeze temperature control accuracy
±0.1 °C
Chamber temperature uniformity
≤ ±1 (unloaded) °C
Antifreeze flow control
1 to 40 / 1 to 25 / 1 to 10 L/min, ±0.2 L/min
Chamber heating rate
≥ 2 °C/min (25 to 100 °C, no load)
Chamber cooling rate
≥ 1 °C/min (25 to -40 °C, no load)

Physical

Chamber size
Upper 220*322*120 cm and lower 220*322*110 cm (GD-9000); single 100*100*100 cm (GD-1000)
Refrigerant
R125 / R404A
Features

Key features

  • 01

    Dual chamber structure

    Independent upper and lower chambers (GD-9000).

  • 02

    Explosion-proof relief

    Door and pressure relief fitted with chains.

  • 03

    Data export

    Acquisition and export supported.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.