Key specifications

Temperature range
0 to 100 / -20 to 100 / -40 to 100 (up to 150 customized) °C
Temperature control accuracy
±0.3 °C
Heating capacity, 0 to 100 °C models
2.5 / 5.5 / 7.5 / 10 / 15 / 25 / 38 kW
Cooling capacity at 100 °C and 20 °C
2.5 / 5.5 / 7.5 / 10 / 15 / 25 / 38 / 60 kW
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

KRY chillers supply antifreeze coolant at a controlled temperature, flow and pressure to power-battery and vehicle component test benches. Normal-temperature models cover 0 to 100 °C; low-temperature models cover -20 to 100 °C and -40 to 100 °C, with an extension to 150 °C available.

Heating capacity ranges from 2.5 to 38 kW and cooling capacity from 2.5 to 60 kW, with flow output of 2 to 50 L/min at ±0.2 L/min accuracy. Each flow channel can be set independently, there is a PLC controller with multi-function alarms, and the system tops up heat-transfer medium automatically at low temperature.

Specifications

Technical specifications

8 parameters

Performance

Temperature range
0 to 100 / -20 to 100 / -40 to 100 (up to 150 customized) °C
Temperature control accuracy
±0.3 °C
Heating capacity, 0 to 100 °C models
2.5 / 5.5 / 7.5 / 10 / 15 / 25 / 38 kW
Cooling capacity at 100 °C and 20 °C
2.5 / 5.5 / 7.5 / 10 / 15 / 25 / 38 / 60 kW

Hydraulics

Flow rate output
2 to 25 L/min (5 to 50 L/min on larger models)
Flow rate accuracy
±0.2 L/min

Control

Temperature display resolution
0.01 K

Electrical

Power supply
380V 50HZ
Features

Key features

  • 01

    Three KRY ranges

    0 to 100, -20 to 100 and -40 to 100 °C.

  • 02

    Flow control ±0.2 L/min

    Adjustable per channel.

  • 03

    Water or air cooled

    W suffix models are water-cooled.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.