Skip to content
Al-Shaker for Scientific and Medical Supplies
Photos available on request

SUNDI W Process Thermostat (-70 to 300 °C)

Compact heater-chiller for microchannel and tubular reactors with small liquid hold-up, covering -70 to 300 °C at ±0.3 °C medium accuracy.

Key specifications

Medium temperature ranges
-5 to 120; -25 to 200; -45 to 250; -70 to 200; -20 to 300 °C
Medium temperature accuracy
±0.3 °C
Heating power
2 / 5.5 / 5.5 / 5.5 / 7.5 kW
Cooling capacity (family)
1.1 to 7.5 kW
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

SUNDI W (also sold under the WTD name) was developed for microchannel and plug-flow reactors, which have small liquid volume, strong heat exchange and a large circulation pressure drop. Models SUNDIW-120, W2-3, W5-4, W7-3 and W2-3V cover -5 to 120, -25 to 200, -45 to 250, -70 to 200 and -20 to 300 °C respectively.

A fully enclosed pipeline reduces refrigerant charge and heat-transfer fluid demand. The control combines feedback PID with a model-free self-building tree algorithm and hysteresis predictor, supports dual temperature display of inlet and outlet, and offers air or water cooling with a plate-heat-exchanger evaporator.

Specifications

Technical specifications

7 parameters

Performance

Medium temperature ranges
-5 to 120; -25 to 200; -45 to 250; -70 to 200; -20 to 300 °C
Medium temperature accuracy
±0.3 °C
Heating power
2 / 5.5 / 5.5 / 5.5 / 7.5 kW
Cooling capacity (family)
1.1 to 7.5 kW

Hydraulics

Flow / pressure max
7 L/min to 25 L/min, up to 3 bar

Physical

Heat transfer medium
Synthetic heat transfer oil

Control

Control mode
Feedback PID + dynamic control calculation, PLC
Features

Key features

  • 01

    Microchannel-matched

    Handles small liquid volume and large pressure drop.

  • 02

    Fully enclosed loop

    Lower fluid and refrigerant demand.

  • 03

    Air or water cooling

    Plate heat exchanger evaporator.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.