Skip to content
Al-Shaker for Scientific and Medical Supplies

PreCiSonic Sonoshaker Ultrasonic Bath with Chiller, Shaker and HMI

Stainless-steel ultrasonic bath at 33 kHz with integrated chiller (5-35 °C) and 0-100 RPM reciprocating shaker, plus programmable shaking and HMI.

Key specifications

Operating frequency
33 +/- 3 kHz
Degassing preset
5 sec
Body and tank
Fully stainless steel
Controller setting range
10 °C to room temperature, max 35 °C
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

This Sonoshaker version combines a fully stainless-steel ultrasonic bath with a built-in chiller, a reciprocating shaker and an HMI. The bath operates at 33 +/- 3 kHz and offers Pulse Sweep Power (PSP) mode for even distribution of ultrasonic energy, a 5-second auto-degassing preset and a digital timer.

The chiller holds 5-35 °C with a digital controller and PT100 sensor. The shaker is motor-driven at 0-100 RPM with a constant 10 mm amplitude, and a float-sensor interlock prevents sonication when water is low. A lid, basket and 6 horizontal bar holders are supplied as standard.

Specifications

Technical specifications

11 parameters

Ultrasonics

Operating frequency
33 +/- 3 kHz
Degassing preset
5 sec

Construction

Body and tank
Fully stainless steel

Temperature

Controller setting range
10 °C to room temperature, max 35 °C
Operating temperature range
5-35 °C
Temperature accuracy
+/- 2 °C

Chiller

Compressor power
450 / 535 W
Compressor capacity
926 / 1077 kcal/h
Compressor type
Hermetically sealed gas compressor

Shaker

Shaking motion
Reciprocating, motor 0-100 RPM, constant amplitude 10 mm

Safety

Water level interlock
Float sensor stops sonication on low water level
Features

Key features

  • 01

    Pulse Sweep Power (PSP) mode

    Even ultrasonic energy distribution

  • 02

    Integrated chiller

    5-35 °C with PT100 sensor

  • 03

    Reciprocating shaker

    0-100 RPM, 10 mm amplitude

  • 04

    Water-level interlock

    Float sensor

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.