Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Reference: S 155-A

Sykam S 155-A Compact Anion Chromatograph

Table-top integrated ion chromatograph for anion analysis with isocratic pump, manual injector, column oven, in-line suppressor and conductivity detector.

Key specifications

Pump system
Isocratic double plunger pump with PEEK pumphead
Injector
Manual injector
Column oven
Integrated column oven
Auto suppressor
Integrated in-line auto-suppressor module
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The S 155-A is a table-top ion chromatograph and an economical, fully functional anion chromatography system delivered as one pre-configured unit. It contains an isocratic ion-chromatography pump, a manual injector, a column oven, an in-line suppressor and a conductivity detector.

For low sample throughput and educational purposes it is an entry-level system without compromising analytical performance. Optional extras are an eluent selection valve and/or an inert gas supply connection for the eluent bottle(s).

Specifications

Technical specifications

7 parameters

Pump

Pump system
Isocratic double plunger pump with PEEK pumphead

Injector

Injector
Manual injector

Oven

Column oven
Integrated column oven

Suppressor

Auto suppressor
Integrated in-line auto-suppressor module

Detector

Conductivity detector measuring range
20 nS/cm – 20000 µS/cm

Options

Eluent selection
Optional eluent selection valve with additional 2000 ml eluent bottle
Inert gas supply
Optional inert gas supply regulator with additional 2000 ml eluent bottle
Features

Key features

  • 01

    Integrated single unit

    Pump, injector, oven, suppressor and detector in one housing.

  • 02

    Entry level

    Suited to low sample throughput and educational use.

  • 03

    Optional upgrades

    Eluent selection valve and inert gas supply.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.