Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: S 714

Sykam S 714 Preparative Quaternary Gradient HPLC System – Stainless Steel Version

Preparative quaternary gradient LC system with a stainless steel flow path, S 1535 pump with built-in quaternary gradient mixer, S 5400 sampling module and S 3255 UV/Vis detector; 400 bar.

Key specifications

Flow rate range
up to 150 or 250 ml/min
Max. pressure
400 bar
Gradient
Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing
Flow path material
Stainless steel
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The S 714 is a preparative quaternary gradient LC system with a stainless steel flow path, built on S 1535 pump with built-in quaternary gradient mixer. It is completed by the S 5400 sampling module (10 ml and 2 ml standard sample loops) and the S 3255 variable-wavelength UV/Vis detector (190 – 800 nm, 0.5 mm path length), and is controlled with PrepCon software.

Quaternary gradients give maximum flexibility, from isocratic elution to complex gradients or binary gradients with additional mobile phases for CIP procedures. The S 1535 pump integrates a gradient mixer with an in-line vacuum degasser for each eluent, ensuring stable gradient formation up to the pump's maximum flow rates.

The system can be expanded with valves, eluent monitors, fraction collectors and additional detectors.

Specifications

Technical specifications

7 parameters

System

Flow rate range
up to 150 or 250 ml/min
Max. pressure
400 bar
Gradient
Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing
Flow path material
Stainless steel
Detector
UV/Vis (190 – 800 nm), pathlength 0.5 mm
Sample injection
Automatic, manual, 10 ml sample loop, 2 ml sample loop
Pump
S 1535 pump with built-in quaternary gradient mixer
Features

Key features

  • 01

    Flow rate range

    up to 150 or 250 ml/min

  • 02

    Pressure

    400 bar

  • 03

    Gradient

    Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing

  • 04

    Expandable

    Add valves, eluent monitors, fraction collectors and detectors.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.