Sykam S 724 Preparative Quaternary Gradient HPLC System – PEEK Version

Preparative quaternary gradient LC system with a PEEK flow path, S 1535 pump (PEEK version), S 5400 sampling module and S 3255 UV/Vis detector; 350 bar.

Key specifications

Flow rate range
up to 150 or 250 ml/min
Max. pressure
350 bar
Gradient
Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing
Flow path material
PEEK
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The S 724 is a preparative quaternary gradient LC system with a PEEK (metal-free, biocompatible) flow path, built on S 1535 pump (PEEK version). It is completed by the S 5400 sampling module (10 ml and 2 ml standard sample loops) and the S 3255 variable-wavelength UV/Vis detector (190 – 800 nm, 0.5 mm path length), and is controlled with PrepCon software.

It suits preparative biochromatography such as ion exchange, hydrophobic interaction, immobilized chelate (IMAC, HisTag) and immunoaffinity chromatography, allowing high-salt, high-molarity buffers and complete pH compatibility.

The system can be expanded with valves, eluent monitors, fraction collectors and additional detectors.

Specifications

Technical specifications

7 parameters

System

Flow rate range
up to 150 or 250 ml/min
Max. pressure
350 bar
Gradient
Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing
Flow path material
PEEK
Detector
UV/Vis (190 – 800 nm), pathlength 0.5 mm
Sample injection
Automatic, manual, 10 ml sample loop, 2 ml sample loop
Pump
S 1535 pump (PEEK version)
Features

Key features

  • 01

    Flow rate range

    up to 150 or 250 ml/min

  • 02

    Pressure

    350 bar

  • 03

    Gradient

    Low-pressure mixing quaternary gradient with in-line vacuum eluent degassing

  • 04

    Expandable

    Add valves, eluent monitors, fraction collectors and detectors.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.