Sykam S 732 Preparative Binary Gradient HPLC System – Stainless Steel Version

Preparative binary gradient LC system with a stainless steel flow path, two S 1525 pumps, S 5400 sampling module and S 3255 UV/Vis detector; 400 bar (300 or 400 bar for the 1000 ml/min version).

Key specifications

Flow rate range
up to 150, 250, 500 or 1000 ml/min
Max. pressure
400 bar (300 or 400 bar for the 1000 ml/min version)
Gradient
High-pressure mixing binary gradient
Flow path material
Stainless steel
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The S 732 is a preparative binary gradient LC system with a stainless steel flow path, built on two S 1525 pumps. It is completed by the S 5400 sampling module (10 ml and 2 ml standard sample loops) and the S 3255 variable-wavelength UV/Vis detector (190 – 800 nm, 0.5 mm path length), and is controlled with PrepCon software.

The S 1525 pumps are available in flow ranges up to 1000 ml/min, and an external low-pressure binary, ternary or quaternary gradient mixer can be added to each. Adding the S 8140 mixer converts one pump into a quaternary gradient pump while the second can be used for large-volume sample uptake.

The system can be expanded with valves, eluent monitors, fraction collectors and additional detectors.

Specifications

Technical specifications

7 parameters

System

Flow rate range
up to 150, 250, 500 or 1000 ml/min
Max. pressure
400 bar (300 or 400 bar for the 1000 ml/min version)
Gradient
High-pressure mixing binary gradient
Flow path material
Stainless steel
Detector
UV/Vis (190 – 800 nm), pathlength 0.5 mm
Sample injection
Automatic, manual, 10 ml sample loop, 2 ml sample loop
Pump
two S 1525 pumps
Features

Key features

  • 01

    Flow rate range

    up to 150, 250, 500 or 1000 ml/min

  • 02

    Pressure

    400 bar (300 or 400 bar for the 1000 ml/min version)

  • 03

    Gradient

    High-pressure mixing binary gradient

  • 04

    Expandable

    Add valves, eluent monitors, fraction collectors and detectors.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.