Sykam S 734 Preparative Quaternary Gradient HPLC System – Stainless Steel Version

Preparative quaternary gradient LC system with a stainless steel flow path, S 1525 pump with S 8140 external gradient mixer, S 5400 sampling module and S 3255 UV/Vis detector; 400 bar (300 or 400 bar for the 1000 ml/min version).

Key specifications

Flow rate range
up to 150, 250, 500 or 1000 ml/min
Max. pressure
400 bar (300 or 400 bar for the 1000 ml/min version)
Gradient
Low-pressure quaternary mixing gradient
Flow path material
Stainless steel
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The S 734 is a preparative quaternary gradient LC system with a stainless steel flow path, built on S 1525 pump with S 8140 external gradient mixer. It is completed by the S 5400 sampling module (10 ml and 2 ml standard sample loops) and the S 3255 variable-wavelength UV/Vis detector (190 – 800 nm, 0.5 mm path length), and is controlled with PrepCon software.

It is the system of choice when routine 24/7 use at flow rates close to the maximum rated flow and at high pressure is expected, thanks to the heavy-duty mechanical concept of the S 1525 pump and the S 8140 gradient mixer.

The system can be expanded with valves, eluent monitors, fraction collectors and additional detectors.

Specifications

Technical specifications

7 parameters

System

Flow rate range
up to 150, 250, 500 or 1000 ml/min
Max. pressure
400 bar (300 or 400 bar for the 1000 ml/min version)
Gradient
Low-pressure quaternary mixing gradient
Flow path material
Stainless steel
Detector
UV/Vis (190 – 800 nm), pathlength 0.5 mm
Sample injection
Automatic, manual, 10 ml sample loop, 2 ml sample loop
Pump
S 1525 pump with S 8140 external gradient mixer
Features

Key features

  • 01

    Flow rate range

    up to 150, 250, 500 or 1000 ml/min

  • 02

    Pressure

    400 bar (300 or 400 bar for the 1000 ml/min version)

  • 03

    Gradient

    Low-pressure quaternary mixing gradient

  • 04

    Expandable

    Add valves, eluent monitors, fraction collectors and detectors.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.