ViBRA MD Moisture Analysers

Loss-on-drying moisture: 80 g / 0.005 g / 0.01 %, organic-carbon heater 2 × 280 W, 30–180 °C — automatic or timed end-point.

Key specifications

Principle
Evaporation weight-loss (MD83)
Capacity
1 to 80 g
Mass / moisture
0.005 g / 0.01 %
Source
Organic-carbon, 2 × 280 W; 30–180 °C
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

MD83 is ViBRA’s routine moisture analyser for laboratory and process: evaporation weight-loss on a stainless 110 mm pan, 1–80 g sample, 0.005 g mass readability and 0.01 % / 0.1 % moisture (0.1 % at a 5 g sample). The range is 0–100 % wet-base (solids) or 0–500 % dry-base. Temperature is 30–180 °C in 1 °C steps. The heat source is an organic-carbon heater, 280 W × 2, tool-free to replace. Automatic mode watches the drying curve and stops; timed mode runs a fixed interval. Five method slots store conditions. A backlit 96 × 40 mm LCD, RS232C, and an alert signal are standard. Peak power is 900 W at 100–120 / 220–240 VAC.

Shinko Denshi pairs auto-taring with the carbon heater for repeatability, and keeps the chamber simple so daily cleaning is a wipe, not a service call. Options include disposable aluminium sheets (DA-1) and a deodorising windshield (FW-100).

Al-Shaker specifies MD for food, pharmaceutical, and materials moisture where a halogen unit is not required, then installs and supports the analyser with the rest of the ViBRA bench.

Specifications

Technical specifications

4 parameters

Principle
Evaporation weight-loss (MD83)
Capacity
1 to 80 g
Mass / moisture
0.005 g / 0.01 %
Source
Organic-carbon, 2 × 280 W; 30–180 °C
Features

Key features

  • 01

    Carbon heater, tool-free swap

    2 × 280 W organic-carbon elements you can change by hand when the lamp is done.

  • 02

    Automatic end-point

    The instrument watches the curve so operators do not have to guess when the sample is dry.

  • 03

    0.01 % moisture on an 80 g pan

    Enough resolution for routine QC without a microbalance and a vacuum oven.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.