Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: HC18T314 / HC18T536

CommaSil® C18-T Hybrid Silica HPLC Column

A C18 HPLC column on hybrid silica with triple bonding and end-capping, offering wide pH stability and high efficiency; five particle sizes from 1.7 to 5 μm and listed as equivalent to Waters BEH C18.

Key specifications

Phase
C18 on hybrid silica with triple bonding and end-capping
pH stability
Wide pH range (hybrid bare-sphere structure)
Equivalent series (per Biocomma)
Waters BEH C18
Particle sizes
1.7, 2.5, 3, 3.5 and 5 μm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

CommaSil® C18-T combines a hybrid silica base with triple-bonding technology to deliver wide pH stability and strong separation performance, which supports a longer column lifetime. The series is described as compatible with all instrument platforms and suited to purifying larger sample amounts, improving method continuity and efficiency.

The hybrid bare-sphere structure expands the usable pH range, while triple bonding and end-capping give high column efficiency and excellent peak symmetry. Strict quality control is intended to give excellent lot-to-lot consistency of sorbent and columns. Biocomma lists the series as equivalent to Waters BEH C18.

Application examples on the page include malachite green and aflatoxin B1 by LC-MS and pantoprazole sodium related substances by HPLC-UV. Particle sizes of 1.7, 2.5, 3, 3.5 and 5 μm are available.

Specifications

Technical specifications

14 parameters

Column

Phase
C18 on hybrid silica with triple bonding and end-capping
pH stability
Wide pH range (hybrid bare-sphere structure)
Equivalent series (per Biocomma)
Waters BEH C18
Particle sizes
1.7, 2.5, 3, 3.5 and 5 μm
Column internal diameters
2.1, 3.0 and 4.6 mm
Column lengths
30, 50, 100, 150 and 250 mm (250 mm in 3.0 and 4.6 mm i.d.; 1.7 μm offered in 2.1 and 3.0 mm i.d.)

Application example

Example: malachite green (LC-MS)
2.1 × 100 mm, 3 μm (HC18T314); 0.3 mL/min; 40 °C; 10 μL; 0.1% formic acid water (5 mmol/L ammonium acetate) / acetonitrile gradient; HESI positive mode
Example: aflatoxin B1 (LC-MS)
2.1 × 100 mm, 3 μm (HC18T314); 0.3 mL/min; 40 °C; 5 μL; ammonium acetate / 0.1% formic acid methanol gradient; HESI positive mode
Example: pantoprazole sodium related substances
4.6 × 250 mm, 5 μm (HC18T536); UV 289 nm; 1 mL/min; 40 °C

Ordering information

Catalog numbers, 1.7μm particles
30×2.1mm HC18T111; 50×2.1mm HC18T211; 100×2.1mm HC18T311; 150×2.1mm HC18T411; 30×3.0mm HC18T121; 50×3.0mm HC18T221; 100×3.0mm HC18T321; 150×3.0mm HC18T421; 250×3.0mm HC18T521
Catalog numbers, 2.5μm particles
30×2.1mm HC18T113; 50×2.1mm HC18T213; 100×2.1mm HC18T313; 150×2.1mm HC18T413; 30×3.0mm HC18T123; 50×3.0mm HC18T223; 100×3.0mm HC18T323; 150×3.0mm HC18T423; 250×3.0mm HC18T523; 30×4.6mm HC18T133; 50×4.6mm HC18T233; 100×4.6mm HC18T333; 150×4.6mm HC18T433; 250×4.6mm HC18T533
Catalog numbers, 3μm particles
30×2.1mm HC18T114; 50×2.1mm HC18T214; 100×2.1mm HC18T314; 150×2.1mm HC18T414; 30×3.0mm HC18T124; 50×3.0mm HC18T224; 100×3.0mm HC18T324; 150×3.0mm HC18T424; 250×3.0mm HC18T524; 30×4.6mm HC18T134; 50×4.6mm HC18T234; 100×4.6mm HC18T334; 150×4.6mm HC18T434; 250×4.6mm HC18T534
Catalog numbers, 3.5μm particles
30×2.1mm HC18T115; 50×2.1mm HC18T215; 100×2.1mm HC18T315; 150×2.1mm HC18T415; 30×3.0mm HC18T125; 50×3.0mm HC18T225; 100×3.0mm HC18T325; 150×3.0mm HC18T425; 250×3.0mm HC18T525; 30×4.6mm HC18T135; 50×4.6mm HC18T235; 100×4.6mm HC18T335; 150×4.6mm HC18T435; 250×4.6mm HC18T535
Catalog numbers, 5μm particles
30×2.1mm HC18T116; 50×2.1mm HC18T216; 100×2.1mm HC18T316; 150×2.1mm HC18T416; 30×3.0mm HC18T126; 50×3.0mm HC18T226; 100×3.0mm HC18T326; 150×3.0mm HC18T426; 250×3.0mm HC18T526; 30×4.6mm HC18T136; 50×4.6mm HC18T236; 100×4.6mm HC18T336; 150×4.6mm HC18T436; 250×4.6mm HC18T536
Features

Key features

  • 01

    Wide pH tolerance

    A hybrid bare-sphere structure expands the usable pH range and supports long column life.

  • 02

    High efficiency and peak symmetry

    Triple bonding and end-capping give high column efficiency and excellent peak symmetry.

  • 03

    Lot-to-lot consistency

    Strict quality control targets consistent sorbent and column performance between lots.

  • 04

    Platform compatibility

    Described as compatible with all instrument platforms.

  • 05

    Five particle sizes

    1.7, 2.5, 3, 3.5 and 5 μm.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.