Skip to content
Al-Shaker for Scientific and Medical Supplies

Copure® 96 Well Protein Phospholipid Removal (PPRP) Plate

96-well plate that precipitates proteins and removes phospholipids in one device, using a drip-free filter membrane and Lipoclean® adsorbent, for LC-MS/MS sample cleanup.

Key specifications

Catalog number
MPPRP9601
Description
Copure® 96 Well PPRP Plate, 40 mg/1 mL/well
Pack quantity
1 pc/box
Catalog number
MPPRP9602
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Copure® 96 Well Protein Phospholipid Removal (PPRP) Plate uses a new drip-free filter membrane to carry out protein precipitation in the wells. It is combined with the Lipoclean® adsorbent so that proteins and phospholipids are removed from the sample at the same time, improving cleanup of lipid-rich samples and the quality of target data while limiting instrument maintenance.

The general procedure takes 2 to 4 steps. In the manufacturer's mass-spectrum comparison, phospholipid intensity in biological samples treated with the plate fell by nearly two orders of magnitude. The plate is applied to TDM (therapeutic drug monitoring), forensic toxicology and endocrine studies.

The range includes 40 mg/1 mL and 40 mg/2 mL per well plates (MPPRP9601, MPPRP9602) and a 40 mg/1 mL cartridge (MPPRP0140, 30 per box).

Specifications

Technical specifications

13 parameters

Ordering

Catalog number
MPPRP9601
Description
Copure® 96 Well PPRP Plate, 40 mg/1 mL/well
Pack quantity
1 pc/box

Ordering (2 mL)

Catalog number
MPPRP9602
Description
Copure® 96 Well PPRP Plate, 40 mg/2 mL/well
Pack quantity
1 pc/box

Ordering (cartridge)

Catalog number
MPPRP0140
Description
Copure® PPRP Cartridge, 40 mg/1 mL/cartridge
Pack quantity
30 pcs/box

General

Sorbent
Lipoclean® adsorbent
Filter
Drip-free technology filter membrane
Procedure
2-4 step general procedure
Reported performance
Phospholipid signal reduced by nearly 2 orders of magnitude in treated biological samples
Features

Key features

  • 01

    Protein and phospholipid removal

    Precipitates proteins and captures phospholipids in the wells to limit ion suppression.

  • 02

    Drip-free filter membrane

    A new drip-free technology filter membrane enables protein precipitation in the wells.

  • 03

    Short procedure

    General procedures take 2 to 4 steps.

  • 04

    Strong phospholipid reduction

    Phospholipid intensity in treated biological samples dropped by nearly 2 orders of magnitude in the published comparison.

  • 05

    Target applications

    Applied to TDM, forensic toxicology and endocrine studies.

  • 06

    Plate or cartridge formats

    Plates of 40 mg/1 mL and 40 mg/2 mL per well, and a 40 mg/1 mL cartridge.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.