Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: COICC1801 / COICRP01 / COICH01

Copure® Cartridges for Ion Chromatography Sample Preparation

Pretreatment cartridges for ion chromatography (C18, RP, H, Ag, Na, Ag/H and Ag/Na) that remove organic, metal and other interfering ions using reversed-phase adsorption or ion exchange.

Key specifications

Catalog number: C18 cartridge
COICC1801; 300 mg; 50 pcs/box
Catalog number: RP cartridge
COICRP01; 1 mL; 50 pcs/box
Catalog number: H cartridge
COICH01; 1 mL; 50 pcs/box
Catalog number: Ag cartridge
COICAG01; 1 mL; 50 pcs/box
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

In ion chromatography, organic compounds, metals and other interfering ions can affect the analysis of target ions. These pretreatment cartridges work on reversed-phase adsorption or ion exchange to remove such interferences effectively and help keep results accurate.

Seven cartridge types are offered: C18 (300 mg), and RP, H, Ag, Na, Ag/H and Ag/Na (1 mL each), supplied 50 pieces per box.

Specifications

Technical specifications

8 parameters

Ordering

Catalog number: C18 cartridge
COICC1801; 300 mg; 50 pcs/box
Catalog number: RP cartridge
COICRP01; 1 mL; 50 pcs/box
Catalog number: H cartridge
COICH01; 1 mL; 50 pcs/box
Catalog number: Ag cartridge
COICAG01; 1 mL; 50 pcs/box
Catalog number: Na cartridge
COICNAO1; 1 mL; 50 pcs/box
Catalog number: Ag/H cartridge
COICAGH01; 1 mL; 50 pcs/box
Catalog number: Ag/Na cartridge
COICAGNAO1; 1 mL; 50 pcs/box

Principle

Removal principle
Reversed-phase adsorption or ion exchange
Features

Key features

  • 01

    Removes interferences

    Organic, metal and other interfering ions are removed before analysis.

  • 02

    Two mechanisms

    Reversed-phase adsorption or ion exchange, depending on cartridge type.

  • 03

    Seven cartridge types

    C18, RP, H, Ag, Na, Ag/H and Ag/Na.

  • 04

    Supports accurate results

    Helps ensure accuracy of ion chromatography results.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.