Copure® HPLC Column for Cyromazine

A Copure® HPLC column (4.6 × 250 mm, 5 μm) on ultra-pure silica with exclusive bonding and end-capping, designed for cyromazine residue analysis in vegetables and animal foods.

Key specifications

Intended analyte
Cyromazine residue
Silica / bonding
Ultra-pure silica with exclusive surface bonding and end-capping
Referenced methods
NY/T 1725-2009 (cyromazine in vegetables); GB 31658.12-2021 (animal foods)
Dimensions
4.6 mm × 250 mm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

The Copure® HPLC column for cyromazine is built on ultra-pure silica with an exclusive surface-bonding and end-capping process. Biocomma positions it for high sensitivity and accuracy in cyromazine detection together with a long service life.

The page states that it meets the requirements for cyromazine residue detection in vegetables under NY/T 1725-2009 and in animal foods under GB 31658.12-2021 (Food Safety National Standard) using high-performance liquid chromatography.

The example method uses water and acetonitrile (5:95) isocratically at 1 mL/min, 35 °C, with UV detection at 215 nm. The column is supplied as one 4.6 × 250 mm, 5 μm unit per box.

Specifications

Technical specifications

7 parameters

Column

Intended analyte
Cyromazine residue
Silica / bonding
Ultra-pure silica with exclusive surface bonding and end-capping

Standards

Referenced methods
NY/T 1725-2009 (cyromazine in vegetables); GB 31658.12-2021 (animal foods)

Ordering information

Dimensions
4.6 mm × 250 mm
Particle size
5 μm
Catalog number
HNHS536 (ordering table); 1 unit/box

Application example

Example method
Water : acetonitrile 5:95 isocratic; 1 mL/min; 35 °C; 20 μL; UV 215 nm
Features

Key features

  • 01

    Dedicated to cyromazine

    Developed specifically for cyromazine residue detection.

  • 02

    Ultra-pure silica

    Exclusive surface bonding and end-capping for high sensitivity and accuracy.

  • 03

    Long service life

    Described as having a long service life.

  • 04

    Standard-method support

    Page states it meets cyromazine residue detection requirements in NY/T 1725-2009 and GB 31658.12-2021.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.