Copure SPE (HLB family)
Biocomma Copure HLB: PS/DVB copolymer, pH 0–14, 500–750 m²/g, 200–400 Å, cartridges from 30 mg/1 mL to 500 mg/12 mL.
View product
Clinical-MS SPE plates in HLB, MCX, MAX, WCX and WAX chemistries, offered as no-dead-volume DVfree plates or classic 96-well formats for automated high-throughput work.
Key specifications
Copure® MS 96-Well Solid Phase Extraction (SPE) Plates
Request a quoteOverview
Copure® MS Series 96-well SPE plates are built for high-throughput clinical mass spectrometry, using Biocomma's own sorbents and core accessories. The sorbents are described as having more uniform particle size, larger specific surface area, higher loading capacity, higher purity and no background impurities, helping to cope with complex biological matrices and very low analyte levels.
Five sorbent chemistries are offered: HLB (balanced reversed-phase for acidic, basic and neutral compounds), MCX and MAX (strong cation / anion exchange) and WCX and WAX (weak cation / anion exchange). Recovery data are published for steroid hormones, catecholamines and vitamins.
Two plate designs are available. DVfree plates have a no-dead-volume structure and 3-5 mg of sorbent per well, with elution volumes as low as 25 µL so that evaporation and reconstitution can be skipped. Regular plates offer 10 mg, 30 mg and other loadings. Both work with Biocomma positive pressure devices and most liquid-handling robots.
Specifications
11 parameters
Versatile hydrophilic-lipophilic-balanced reversed-phase sorbent for acidic, basic and neutral compounds.
Strong cation exchange (MCX, selective for weakly basic compounds) and strong anion exchange (MAX, selective for weakly acidic compounds) reversed-phase sorbents.
Weak cation exchange (WCX, strongly basic compounds) and weak anion exchange (WAX, strongly acidic compounds) reversed-phase sorbents.
No dead volume and no solvent residue reduce analyte loss; 3-5 mg of evenly packed sorbent per well suits trace-level extraction.
Elution volumes as low as 25 µL remove the need for evaporation and reconstitution.
Classic plate design in 10 mg, 30 mg and other loadings for high sample capacity.
Compatible with Biocomma positive pressure devices and most liquid-handling robotic systems.