Skip to content
Al-Shaker for Scientific and Medical Supplies
1 / 2

Copure® Mycotoxin Clean-up Columns

Pass-through clean-up columns that adsorb lipids, organic acids, proteins and pigments while letting the target mycotoxin through, finishing purification in about 30 seconds; seven versions.

Key specifications

Principle
Multiple adsorption matrices adsorb lipids, organic acids, proteins and pigments; targets pass through
Processing time
Purification in 30 s
Storage
Room temperature, more than 18 months
Precision
RSD ≤ 5%
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Copure® Mycotoxin clean-up Columns contain multiple adsorption matrices that quickly and selectively retain lipids, organic acids, proteins, pigments and other impurities. The matrices do not retain the target analyte, so purification is fast.

The workflow is simple: extract the sample, add the extract to a test tube, insert the rubber-tipped end of the column into the tube, push the column to the bottom, and the purified sample passes through the sorbent to the top of the column. After concentration it is ready for analysis. Biocomma notes purification within 30 seconds, room-temperature storage for more than 18 months and RSD of 5% or less. In an example, aflatoxin B1 in peanut oil at 20 µg/kg gave an average recovery of 82.9% with an RSD of 1.7%.

Seven versions cover patulin and aflatoxins (228), zearalenone with aflatoxins (226), zearalenone alone (224), aflatoxins M1 and M2 (223), deoxynivalenol (230), ochratoxin A (229) and multiple functions (302), each at 25 per box.

Specifications

Technical specifications

12 parameters

Product

Principle
Multiple adsorption matrices adsorb lipids, organic acids, proteins and pigments; targets pass through
Processing time
Purification in 30 s
Storage
Room temperature, more than 18 months
Precision
RSD ≤ 5%

Application example

Example result
Aflatoxin B1 in peanut oil at 20 µg/kg: recoveries 81.9 / 84.5 / 82.4%; average 82.9%; RSD 1.7%

Ordering information

COAF228-E
Patulin, aflatoxin B1, B2, G1, G2; 25 pcs/box
COAF226-E
Zearalenone, aflatoxin B1, B2, G1, G2; 25 pcs/box
COAF224-E
Zearalenone; 25 pcs/box
COAF223-E
Aflatoxin M1, M2; 25 pcs/box
COAF230-E
Deoxynivalenol; 25 pcs/box
COAF229-E
Ochratoxin A; 25 pcs/box
COAF302-E
Multiple functions; 25 pcs/box
Features

Key features

  • 01

    Fast purification

    Purification completed in 30 seconds.

  • 02

    Simple operation

    Push the column into the extract tube; the purified sample passes through the sorbent.

  • 03

    Multi-matrix adsorption

    Retains lipids, organic acids, proteins and pigments without retaining the target.

  • 04

    Room-temperature storage

    Can be stored at room temperature for more than 18 months.

  • 05

    Repeatable

    RSD of 5% or less; 1.7% in the aflatoxin B1 peanut-oil example.

  • 06

    Seven versions

    For aflatoxins, zearalenone, patulin, deoxynivalenol, ochratoxin A or multiple functions.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.