Skip to content
Al-Shaker for Scientific and Medical Supplies

Reference: COPSA3500 / COPSA6500

Copure® PSA Primary-Secondary Amine SPE Cartridges

Primary-secondary amine SPE cartridges with weak anion exchange and normal-phase retention and higher ion exchange capacity than NH2, for cleanup of food matrices.

Key specifications

Functional group
Primary-secondary amine (PSA), pKa 10.1 and 10.9
Surface area
500 m²/g
Carbon content
8 %
Particle size
50-75 µm
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Like NH2, Copure® PSA (primary-secondary amine) has weak anion exchange and normal-phase retention. Its two amine groups, with pKa values of 10.1 and 10.9, give a greater ion exchange capacity and let it extract polar compounds through amine bonds. PSA also forms complexes with metal ions, so it can retain certain metal cations.

The sorbent effectively removes many interfering components from food. Applications include removing fatty acids (oleic, palmitic and linoleic acids), organic acids, certain pigments, metal ions and sugar interferences from food matrices, and detection of sedative drugs in bodily fluids.

Specifications

Technical specifications

8 parameters

Sorbent

Functional group
Primary-secondary amine (PSA), pKa 10.1 and 10.9
Surface area
500 m²/g
Carbon content
8 %
Particle size
50-75 µm
Pore size
70 Å

Ordering

Catalog numbers
COPSA1100, COPSA3100, COPSA3200, COPSA3500, COPSA6200, COPSA6500, COPSA61000, COPSA121000, COPSA122000
Cartridge formats
100 mg/1 mL (100 pcs/box); 100 mg/3 mL (50 pcs/box); 200 mg/3 mL (50 pcs/box); 500 mg/3 mL (50 pcs/box); 200 mg/6 mL (30 pcs/box); 500 mg/6 mL (30 pcs/box); 1000 mg/6 mL (30 pcs/box); 1000 mg/12 mL (20 pcs/box); 2000 mg/12 mL (20 pcs/box)
Equivalent to (per Biocomma)
Agilent Bond Elut PSA
Features

Key features

  • 01

    Higher capacity than NH2

    Two amine groups give greater ion exchange capacity.

  • 02

    Food matrix cleanup

    Removes fatty acids, organic acids, certain pigments, metal ions and sugars.

  • 03

    Metal ion complexation

    Forms complexes with metal ions, retaining certain cations.

  • 04

    Bodily fluid analysis

    Detection of sedative drugs in bodily fluids.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.