Egg Yolk Tellurite Enrichment

Egg yolk and potassium tellurite supplement for selective isolation and enumeration of coagulase-positive staphylococci on Baird-Parker Agar.

Key specifications

Product code
TJ005F
Form
Supplement vial
Use
Add each vial to 100 mL of Baird-Parker Agar Base (GF1024F / KL1024F) and mix thoroughly to prepare Baird-Parker Agar
Egg yolk saline
30%
  • Configured to your application by our specialists
  • Installed and commissioned on site
  • Training and after-sales support across Jordan, the GCC and MENA

Overview

Product overview

Egg Yolk Tellurite Enrichment (TJ005F) is a supplement for the selective isolation and enumeration of coagulase-positive staphylococci. It consists of 30% egg yolk saline and a 1% potassium tellurite solution.

Each vial is added to 100 mL of Baird-Parker Agar Base (GF1024F / KL1024F) and mixed thoroughly to prepare Baird-Parker Agar. Store dark and dry at 2-8 °C; sealed product has a 1-year shelf life.

Specifications

Technical specifications

8 parameters

Identification

Product code
TJ005F
Form
Supplement vial

Preparation

Use
Add each vial to 100 mL of Baird-Parker Agar Base (GF1024F / KL1024F) and mix thoroughly to prepare Baird-Parker Agar

Composition

Egg yolk saline
30%
Potassium tellurite solution
1%

Storage & handling

Storage
Store in a dark, dry place at 2-8 °C.
Shelf life (sealed product)
1 year
Precautions
Not for clinical use. After use, autoclave all contaminated materials at 121 °C for 30 minutes before disposal.
Features

Key features

  • 01

    Coagulase-positive staphylococci

    For selective isolation and enumeration of coagulase-positive staphylococci.

  • 02

    Two components

    30% egg yolk saline and 1% potassium tellurite solution.

  • 03

    Baird-Parker preparation

    Add one vial per 100 mL of Baird-Parker Agar Base (GF1024F / KL1024F).

  • 04

    Cold storage

    Store dark and dry at 2-8 °C; shelf life of sealed product is 1 year.

From order to operation

We stay with the instrument after it arrives

Al-Shaker specifies the configuration, documents the system, and supports it across Jordan, the GCC, and MENA.

  1. 01

    Consult

  2. 02

    Plan

  3. 03

    Supply

  4. 04

    Install

  5. 05

    Train

  6. 06

    Support

Talk to the technical team

Tell us the application. We will specify the system.

Share the workflow, capacity, and compliance constraints. We respond with a recommended configuration, not a generic catalogue list.